Troubleshooting – Karcher BP 2 Garden User Manual
Page 22
– 7
6.997-341.0 Suction filter with
backflow stop, pre-
mium
To be connected to the suction hose meter
length. The backflow stop prevents the return
flow of the transported water and thus shortens
the re-suction time.
Durable metal/plastic construction. Suitable for
3/4“ (19 mm) and 1“ (25.4 mm) hoses.
Including hose clamp.
6.997-340.0 Connection kit Pre-
mium
For the connection of 3/4" (19 mm) water hos-
es to pumps with G1 (33.3 mm) connection
threads. For increased water flow.
2.645-007.0/
2.645-066.0
G1 tap connection
with G3/4 reducer
Particularly sturdy tap connection. Reducer al-
lows the connection to 2 thread sizes.
2.645-193.0/
2.645-203.0
Universal hose
coupling Plus, for
1/2", 5/8" and 3/4"
hoses
Recessed grips made of soft plastic ensure
easy handling. Universally useable for all com-
mon garden hoses.
2.645-148.0 Hose PrimoFlex
plus, 25 m, 3/4"
Phthalate-free 3/4" garden hose for connecting
the pump with the application equipment.
Troubleshooting
ṇ
Caution
To avoid risks, all repairs and replacement of spare parts may only
be carried out by authorized customer service personnel.
First pull out the plug from the mains before carrying out any tasks
on the machine.
Fault
Cause
Remedy
Pump runs but does not
transport
Air in the pump
see chapter "Prepara-
tion" fig. B and and chap-
ter "Operations" fig. D
Suction area blocked
Pull out the mains plug
and clean the suction
area
Suction hose or connection
adapter not screwed in cor-
rectly or completely.
Manually tighten the suc-
tion hose and the con-
nection adapter.
Pump does not run or
suddenly comes to a
standstill during opera-
tions
Power supply interrupted
Check fuses and electri-
cal connections
Thermal protection switch has
switched off the pump due to
over-heating
(Only with BP 4 Garden Set).
Pull out the mains plug,
let the pump cool down,
clean the suction area,
prevent dry running
22