– 10
Filter has not been fastened correctly or is
defective.
Check to see if filter is sitting properly;
replace if required.
Filter is blocked.
Switch off the appliance, clean the filter.
The mains plug is plugged in and the mains
voltage is applied.
Suction turbine rotates in the wrong di-
rection; interchange poles at the plug.
Glows when the emergency stop button is
pressed.
Release emergency-stop button by
turning.
Glows when the motor safety switch has
been triggered to due increased power
consumption.
Turn On/Off switch to 0, wait for approx.
10 minutes, turn the on/off switch to 1.
If malfunction can not be fixed, the de-
vice must be checked by customer ser-
vice.
The warranty terms published by the rele-
vant sales company are applicable in each
country. We will repair potential failures of
your appliance within the warranty period
free of charge, provided that such failure is
caused by faulty material or defects in man-
ufacturing. In the event of a warranty claim
please contact your dealer or the nearest
authorized Customer Service centre.
Please submit the proof of purchase.
ƽ
Danger
Only use accessories approved for the us-
age of design 22 by the manufacturer. The
use of other accessories may pose a risk of
explosion.
–
Only use accessories and spare parts
which have been approved by the man-
ufacturer. The exclusive use of original
accessories and original spare parts
ensures that the appliance can be oper-
ated safely and trouble free.
–
At the end of the operating instructions
you will find a selected list of spare parts
that are often required.
–
For additional information about spare
parts, please go to the Service section
at www.kaercher.com.
Dust comes out while vacuuming
Pressure gauge indicates improper
pressure
Indicator lamp "mains voltage" is
on
Fault display IV 100/40 M B1, IV 100/
55 M B1
Indicator lamp "direction of rotation in-
correct" is on
Fault display IV 100/75 M B1
The indicator lamp "Emergency stop
button actuated" is on
Indicator lamp "Motor failure" is on
Customer Service