– 3
Wind the high pressure hose in uniform
layers on the hose drum by rotating the
crank. Select the rotation direction in
such a way that the high pressure hose
does not get bent.
ṇ
Danger
–
Danger of injury by electric shock.
–
The appliance should always be con-
nected to the electrical mains using a
plug. It is forbidden to permanently con-
nect the appliance to the power supply.
The plug is only for mains separation.
–
The plug and coupling of the extension
cable used must be watertight.
–
Use the extension cord that has an ad-
equate cross-section (see "Technical
Data") and unwind it fully from the cable
drum.
For connection values, see type plate/tech-
nical data.
Unwind the mains cable and place it on
the floor.
Insert the mains plug into a socket.
ṇ
Warning
Observe regulations of water supplier.
According to the applicable regula-
tions, the appliance must never be
used on the drinking water supply
without a system separator. Use a
suitable system separator manufactured by
KÄRCHER; or, as an alternative, a system
separator as per EN 12729 Type BA. Water
flowing through a system separator is con-
sidered non-drinkable.
Caution
Always connect the system separator to
the water supply, never directly to the appli-
ance!
For connection values refer to technical
specifications
Connect the supply hose (max length
7.5 m, minimum diameter 1/2“) to the
water connection point of the machine
and at the water supply point (for e.g. a
tap).
Note
The supply hose is not included.
Open the water supply.
Screw the suction hose with filter (order
no. 4.440-238.0) to the water connec-
tion.
Appliance ventilation:
Unscrew the nozzle from the spray
pipe.
Switch on the appliance and let it run
until the water exiting is bubble-free.
Let the appliance run for 10 seconds –
then switch off the appliance switch.
Repeat the procedure several times.
Switch off the appliance and fit the noz-
zle again.
ƽ
Danger
Risk of explosion!
Do not spray flammable liquids.
If the appliance is used in hazardous areas
(e.g. filling stations) all of the safety provi-
sions and operating instructions detailed in
this manual must be observed.
ƽ
Danger
Long hours of using the appliance can
cause circulation problems in the hands on
account of vibrations.
It is not possible to specify a generally valid
operation time, since this depends on sev-
eral factors:
–
Proneness to blood circulation deficien-
cies (cold, numb fingers).
–
Low ambient temperature. Wear warm
gloves to protect hands.
–
A firm grip impedes blood circulation.
Start up
Electrical connection
Water connection
Connection to the water supply
Drawing in water from open reservoirs
Operation
19
EN
- HD 5-15 CX Plus HD 6-13 C HD 5-17 C HD 5-12 C Plus HD 5-17 CX Plus HD 5-17 C Plus HD 6-13 CX Plus HD 5-15 C HD 5-15 C Plus HD 5-12 CX Plus HD 6-13 C Plus HD 5-15 CX EU HD 5-15 EU HD 6-13 CX Plus EU Nettoyeur haute pression HD 6-13 C+ Nettoyeur haute pression HD 5-15 C+ Nettoyeur haute pression HD 5-15 CX+ Nettoyeur haute pression HD 5-13 C Nettoyeur haute pression HD 5-15 C+ avec FR Classic Nettoyeur haute pression HD 5-13 C+ avec FR Classic Nettoyeur haute pression HD 6-13 CX+ Nettoyeur haute pression HD 5-13 CX+ Nettoyeur haute pression HD 5-17 C HD 5-15 CX Plus + FR Classic HD 5-15 C Plus + FR Classic