beautypg.com

Vzn v series, Installation (continued), Rinse valve connection – A.J. Antunes & Co VZN-441V-T5 9700751 User Manual

Page 12: System inlet connection, Filtered water permeate outlet connection, Inlet water plumbing

background image

VZN V SERIES

12

P/N 1011079 Rev. I 12/13

INSTALLATION (continued)

CAUTION

Do NOT use the Rinse Valve for consumable water.

3/4”

Garden

Hose

Connection

3/4”

Garden Hose

(not supplied)

directed

to drain

Rinse Valve Connection

Inlet

Ball Valve

(Manual)

Outlet

Ball Valve

(Manual)

Figure 5. Rinse Valve Connection

Figure 6. Inlet and Outlet Connections

Figure 6a. Installing a T-Fitting for Sanitizing

Rinse Valve Connection

1. Obtain a length of 3/4” garden hose long enough to

reach from the Rinse Valve to the drain.

2. Install a gasket in the end of the hose (non-drain end).

3. Connect the hose to the Rinse Valve fitting. Use a back-

up wrench on the fitting if required (Figure 5).

4. Direct the other end of the hose to the drain. Secure as

necessary.

NOTE: The drain MUST accommodate a flow of up to

15 gpm.

System Inlet Connection

The System Inlet has a 3/4” NPT male thread at the Inlet

Valve (Figure 6). Do NOT overtighten fittings as this could

cause the plastic ball valve to crack.

Use plastic fittings and a pipe thread sealant approved for use

on PVC fittings when making connections.

Filtered Water Permeate Outlet Connection

The System Outlet has a 3/4” NPT female thread at the Outlet

Valve (Figure 6). Do NOT overtighten fittings as this could

cause the plastic ball valve to crack.

Use plastic fittings and a pipe thread sealant approved for use

on PVC fittings when making connections.

Inlet Water Plumbing

The "T" Fitting with plug (supplied) should be installed at the

System Inlet. This fitting will be used for sanitizing the system

and downstream plumbing (Figure 6a).
Before connecting the fitting to the System Inlet, the plumb-

ing to the system must be flushed clear of all debris. Hold a

bucket at the inlet water line and slowly open the Inlet Water

Valve. Allow the pipe to flush until all debris is removed.

Sanitation

Plug

Inlet

Inlet Ball

Valve

T-Fitting

This manual is related to the following products: