UFC SERIES watER FIltRatIon SyStEm

4

P/N 1010907 Rev. A 03/12

A.J. Antunes & Co.

ImpOrtant safetY InfOrmatIOn (continued)

The following warnings and cautions appear throughout

this manual and should be carefully observed.

• Turn the unit off and disconnect the power source

before performing any service or

maintenance on the unit.

• The equipment should be grounded according to

local electrical codes to prevent the possibility of

electrical shock. It requires a grounded recep-

tacle with separate electrical lines, protected by

fuses or circuit breaker of the proper rating.

• All electrical connections must be in accordance

with local electrical codes and any other appli-

cable codes.

• WARNINg eLecTRIcAL shocK hAzARD.

FAILURE To FoLLoW THESE INSTRUCTIoNS

CoULD RESULT IN SERIoUS INJURY oR

DEATH.

- Electrical ground is required on this

appliance.

- Do not modify the power supply cord plug. If

it does not fit the outlet, have a proper outlet

installed by a qualified electrician.

- Do not use an extension cord with this appli-

ance.

- Check with a qualified electrician if you are in

doubt as to whether the appliance is properly

grounded.

• If the supply cord is damaged, it must be

replaced by the manufacturer or its service agent

or a similarly qualified person.

• This equipment is to be installed to comply with

the local plumbing code and any other applicable

code.

• Water pressure must not exceed the membrane

differential pressure of 45 psig (3.1 bar). To

reduce water pressure, install a water pressure

regulator and set the system inlet water pressure

to 45 psi (3.1) bar.

Inlet water

pressure

(psi)

Inlet turbidity

(ntU)

required additional equipment

Installed

water Use

(Gallons per

Day)

flush program

Less than 45 psi

Less than 1 NTU Required: No additional equipment

Recommended: Inlet water strainer

(150 micron/ 100 mesh screen)

Recommended: Permeate Tank

Less than

300 GPD

Greater than

300 GPD

Flush Program:

Interval: 6 hour

Duration: 15 seconds

Flush Program:

Interval: 1 hour

Duration: 15 seconds

Greater than

45 psi

Less than 1 NTU Required: Pressure regulator

Recommended: Inlet water strainer

(150 micron/ 100 mesh screen)

Recommended: Permeate Tank

Less than

300 GPD

Greater than

300 GPD

Flush Program:

Interval: 6 hour

Duration: 15 seconds

Flush Program:

Interval: 1 hour

Duration: 15 seconds

Less than 45 psi

Greater than

1 NTU

Required: Inlet water strainer (150

micron/ 100 mesh screen)

Required: Permeate Tank

Any

Flush Program:

Interval: 1 hour

Duration: 15 seconds

Greater than

45 psi

Greater than

1 NTU

Required: Pressure regulator

Required: Inlet water strainer (150

micron/ 100 mesh screen)

Required: Permeate Tank

Any

Flush Program:

Interval: 1 hour

Duration: 15 seconds

water cOnDItIOn eqUIpment GUIDelInes