VAriety SteAMer (VS-250)
P/N 1010591 Rev. E 03/12
A.J. Antunes & Co.
Daily cleaning
nOte: frequency of cleaning is determined by
water conditions, usage, and water filter systems.
1. turn the power off, unplug the power cord, and
allow the unit to cool for 30 minutes.
2. Check the Quick Disconnect Insert and all hose
clamp connections for leakage. if leakage is
apparent, tighten all clamps or replace part(s) if
required.
nOte: three spare O-rings are attached to the
water hose.
3. turn off the water supply.
4. Remove the water hose from the unit by pressing
down on the tab on the Quick Disconnect Body
on the rear of the unit.
5. Remove the Needle Plate by pushing the Lock
Lever Knob on the right of the unit and lifting the
plate (figure 3).
6. Remove the O-ring from the Needle Plate.
7. Wash all removed parts in soap and hot water,
rinse in clear water, and allow to air dry.
8. Wipe the entire unit with a hot, damp cloth.
nOte: Do nOt use a dripping wet cloth. wring it
out before use.
9. Reinstall all parts and plug in the power cord to
return to service.
lock lever Knob
unlock
figure 3. lock lever Knob
cautIOn
failure to regularly and/or properly clean this
equipment may damage it or cause the user
bodily injury.
warnInG
refer to the instructions for cleaning and handling
the unit within the Important safety Information
section of this manual.