Programming, Figure 4. control programming sequence – A.J. Antunes & Co DFWF-250 9100156 User Manual
Page 7
7
P/N 1010678 Rev. K 08/12
PROGRAMMING
CYC (Total Cycle Time) refers to the total
amount of steaming time set for the product.
SHO (Shot Interval Time) is the time set
between shots of steam during a complete
cycle.
H2O Setting (Steam Shot Time) is used to
adjust the water volume used during each
pump/solenoid operation.
The amount of steam produced by your
Deluxe Food Warmer (steamer) depends on
the amount of water sprayed onto the steam
generator.
Flooding of the Generator may occur if the
H2O setting is set too high. To prevent this
from occurring, the Shot Interval Time (SHO)
may be increased to allow more time for
generator heat recovery. Adjustments should
be made to both values to determine the opti-
mum settings for your cooking needs.
To program the control, refer to Figure 4 and
use the following procedure in sequence:
1. Turn the power on. The display shows
the factory programmed Total Cycle
Time in minutes and seconds (Item A,
Figure 4).
2. Press and release the PROGRAM
button to change the control from
Operation to Program mode.
3. To change the Total Cycle Time in min-
utes, use the UP or DOWN ARROW
buttons to change the time (Item B,
Figure 4).
4. Press and release the PROGRAM but-
ton again and use the UP or DOWN
ARROW buttons to change the Total
Cycle Time in seconds (Item C, Figure
4).
5. To change the SHO factory settings,
make sure the control is in Program
mode, then press and hold the two
ARROW buttons simultaneously for
1-2 seconds and then release. SHO will
be displayed (Item D, Figure 4).
6. Press and release the PROGRAM but-
ton and use the UP or DOWN ARROW
buttons to change the SHO setting in
seconds (Item E, Figure 4).
NOTE: 20 seconds is recommended.
7. Press and release the PROGRAM but-
ton again and use the UP or DOWN
ARROW buttons to change the SHO
setting in minutes (Item F, Figure 4).
NOTE: 00 minutes is recommended.
Figure 4. Control Programming Sequence
8. Press and release the PROGRAM
button again and “H2O” is displayed
(Item G, Figure 4).
9. To change the H2O setting, press and
release the PROGRAM button again to
display the setting (Item H, Figure 4).
Use the UP or DOWN ARROW buttons
to increase or decrease the time.
NOTE: Recommended settings are :
• DFW/DFWT/DFWF-250 [0_50]
• DFW/DFWT-150 [0_08]
10. Press either the START/STOP or
OPERATE button to store the changes
and to exit the Program mode.
NOTE: The START/STOP or OPERATE button
may be pressed at any time during pro-
gramming to store the changes and exit
the Program mode.
NOTE: If no change is made within 5 sec-
onds at any time during the programming
process, all changes made up to that point
are stored in memory and the control
reverts to the Operation mode.
READY
UP
DOWN
PROGRAM
START/STOP
POWER
1500
READY
UP
DOWN
PROGRAM
START/STOP
POWER
15
READY
UP
DOWN
PROGRAM
START/STOP
POWER
00
READY
UP
DOWN
PROGRAM
START/STOP
POWER
SHO
READY
UP
DOWN
PROGRAM
START/STOP
POWER
00
READY
UP
DOWN
PROGRAM
START/STOP
POWER
20
READY
UP
DOWN
PROGRAM
START/STOP
POWER
H2O
READY
UP
DOWN
PROGRAM
START/STOP
POWER
0_80
A. Total Cycle Time
E. SHO Time Seconds
E. SHO Time Minutes
B. Total Cycle Minues
C. Total Cycle Seconds
G. H2O Cycle
G. H2O Setting
D. SHO Cycle
- DFWF-250 9100147 DFWF-250 9100146 DFWT-250 9100136 DFWT-250 9100135 DFWT-250 9100134 DFWT-200 9100133 DFWT-200 9100132 DFWT-200 9100131 DFWT-150 9100128 DFWT-150 9100126 DFWT-150 9100125 DFWT-150 9100124 DFWT-100 9100123 DFWT-100 9100122 DFWT-100 9100121 DFW-250 9100116 DFW-250 9100115 DFW-250 9100114 DFW-200 9100118 DFW-200 9100113 DFW-200 9100112 DFW-200 9100111 DFW-150 9100107 DFW-150 9100106 DFW-150 9100105 DFW-150 9100104 DFW-100 9100103 DFW-100 9100102 DFW-100 9100101