Miracle steamer, Troubleshooting – A.J. Antunes & Co MS-355 9100486 User Manual
Page 13
MIRACLE STEAMER
13
P/N 1010456 Rev. C 08/12
A.J. Antunes & Co.
TROUBLESHOOTING
WARNING
To avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equip-
ment should be performed by qualified service personnel. The unit should be unplugged when servicing,
except when electrical tests are required.
Problem
Possible Cause
Corrective Action
Control Display is blank (power is on
but indicator light is off).
The power cord is not correctly
plugged in.
Plug the power cord into the appro-
priate outlet.
The power cord and/or electrical
plug is damaged.
Inspect electrical wire, plug, and
receptacle.
The main electrical panel circuit
breaker is off or has been tripped.
Reset circuit breaker. Contact your
maintenance person or Authorized
Service Agency if it trips again.
Switch is inoperable.
Contact your maintenance person or
Authorized Service Agency for
service.
Control Display is blank (power is on
and indicator light is on).
Control Board is inoperable
Contact your maintenance person or
Authorized Service Agency for
service.
Transformer is inoperable.
Loose, burnt, or broken wires in
circuit.
Unit does not heat up (Control
Display is on).
Hi-Limit Thermostat is tripped or
inoperable.
Reset the Hi-Limit Thermostat
according to the Operations sec-
tion of this manual. If the Hi-Limit
Thermostat requires continuous
resetting, contact your Authorized
Service Agency for service.
Solid State Relay is inoperable.
Thermocouple is inoperable.
Control Board is inoperable.
Steam Generator is inoperable.
Loose, burnt, or broken wires in
circuit.
The unit’s main electrical panel
circuit breaker trips.
Damaged receptacle, plug, or cord;
a loose connection; or an internal
component failure.
Turn the unit off, allow it to cool to
room temperature, and then restart.
Contact your maintenance person
or Authorized Service Agency if the
condition repeats.
Water leaking inside electrical
housing.
Pinhole leak in rubber hoses.
Replace hoses.
Loose or damaged water line tubes
and/or fittings inside electrical
housing.
Tighten or replace tubes and/or
fittings.
“
ERR” appears in the Control
Display.
Programming and/or SHO and
H2O values were adjusted/changed
improperly.
Reset the Control Board as
described in the Programming sec-
tion of this manual. See Fault Codes.