problem

possible cause

corrective action

unit floods overnight and/or

continues to steam even when

in idle mode.

solenoid Valve is leaking due

to debris trapped inside the

plunger.

attempt to flush the debris out of the valve by

rapidly operating the unit on a number of single

shot cycles and then letting it rest. if the unit

still leaks, disassemble the solenoid Valve

and clean out the plunger. Reassemble unit

and test. if a leak is still present, replace the

solenoid Valve. contact your maintenance

person or authorized service agency.

solenoid Valve is installed

incorrectly.

if the solenoid Valve was replaced, verify that

the “iN” and “Out” labels on the valve corre-

spond to the water flow.

there is no pre-strainer or filter

on the water line just before the

unit .

equipment was supplied with a strainer. if

missing, install strainer.

trOUbleshOOtinG (continued)