Attention! Once descaling is ended, do not leave the descaling liquid in the tank.
• To eliminate the acid solution, lose hold inlet and outlet nuts and wait to the liquid leaves. Beware with

the residual acidity, in order not to damage the pavement or other surfaces.

• Once the antiscale treatment is finished, a neutralizing washing for the residual acidity is required with

the Rothenberger Neutralizing powder.

• Connect the sanitary water inlet and lose hold the outlet. Flush the water heater with fresh water.
• Finally connect the sanitary water outlet and flush with clean water once more

Important! Colour change from red into yellow-orange will indicate that the descaling capability

is exhausted.
If the pump is not used for a period of time, wash out the pump after use by circulating clean water
through it.
Our equipments are constructed with high quality acid resistant materials and submitted to severe
operating tests. Follow the above instructions to avoid any operating or servicing problems.

PROGRAMMING (only ROMATIC 20)

The pump is turned on through the switch placed on the box. When turning on, the led of “OPERATE

HOURS” will start flashing and will be on 0; press the keys DX or SX to carry out the manual starting of the
pump; the value

1 will be seen on the display.

To carry out automatic programming, follow the instructions below:
1) By pressing the key +BACKFLOW INTERV. MIN” the value 1 will be fixed on the display; this means

that flow reversion will be carried out every minute.

2) To change the value press once the key +, the value will start flashing; only during this time, by pressing

the key

+ again, this value can be increased (up to 9). After 3 seconds the value is confirmed.

3) The value on the display decreases as minutes go by. To know the real value set at the beginning press

the key + for 1 minute and the real value will start flashing.

4) To change the value of “OPERATE HOURS” follow the above mentioned instructions of sections

2 and 3.

5) During automatic functioning, press the keys SX or DX twice in succession to proceed to manual mode.
6) Once the time set on the display “OPERATE HOURS” is ended, the pump will stop working and the

display will start flashing and show the value

0.

7) To restart the pump press DX or SX; the pump will start working in manual mode and the value 1 will

be seen on the display “

OPERATE HOURS”.

Accessories


The relevant accessories and an order form can be found from Page 30 onwards.

Disposal


Components of the unit are recyclable material and should be put to recycling. For this purpose registered
and certified recycling companies are available. For an environmental friendly disposal of the non-recyclable
parts (e.g. electronic waste) please contact your local waste disposal authority.

ENGLISH