9

ENGLISH

OPERATING INSTRUCTIONS

Warning

• Use clean fresh water only and/or non-aggressive liquids.
• Once wanted pressure is reached, avoid the power pump running for more

than 3 minutes.

Though switched on, the motor does not start running

Current does not reach the motor
terminal box

Check plug/socket contact. Check cord wires integrity up to
terminal box. Reset the electrical feeding cut by motor thermal
protection and/or replace blown fuses.

Current reaches the motor terminal box,
however with too low voltage

Arrange for motor to be fed with correct 230V, 50 Hz (110 V.) electric
current

Pump jammed up or stuck by ice.
Motor rotor stuck

Apply to an appointed Service Center

Pump runs, however without making pressurised water

Pump is fed with too small quantity of
water

Check the feeding water hose: its inner diameter must be min. 15
mm.. Moreover the feeding water has to fl ow from cock with min.
pressure of 1 bar

Considerable quantity of air mixed with
inlet water

Put a vented storage tank in the water feeding line between cock and
water inlet with the pump

Water fi lter clogged

Clean the fi lter

Pump water seals worn out or pump valves
jammed

Apply to an appointed Service Center

Valve V1 at the minimum point of pressure Turn the valve V1 till reaching the wanted pressure

Irregular pressure output combined to considerable noise

Air mixed with feeding water

Check tightness at both ends of feeding water hose

Pump is fed with too small quantity of
water

Check the feeding water hose: its inner diameter must be min. 15 mm.
Moreover the feeding water has to fl ow from cock with min. pressure
of 1 bar

Motor suddenly stops running

Motor overheating (motor thermal
protection stops it)

Let the overheated motor cool down and then switch it on again

Pump gets the tested piping pressurised but cannot keep wanted pressure

Valve V2 does not perform properly

Check the functioning of the valve V2. Clean it and remove dirt that
water may have carried inside

Fault, possible causes, repairs