ROTHENBERGER RODIADRILL 1800 DWS User Manual
Page 17
ENGLISH
13
Always wear protective goggles when working with the equipment. We recommend protective
gloves, sturdy, non-slip shoes and an apron.
Shavings or chips must not be removed when the equipment is running.
Dust that arises during work is often harmful to health and should not be allowed to enter the
body. Please wear a suitable dust protection mask.
Please remove the plug from the electric socket before all work on the equipment.
Be sure the equipment is switched off before connecting it to the electric socket.
Always keep the connecting cable away from the sphere of action of the equipment. Always
guide the cable away from the equipment to the rear.
Please look out for electric cables, gas and water pipes when working on the wall, ceiling or
floor.
2
Technical Data
1400 DWS
1800 DWS
Nominal acceptance power ......... 2000 W
2500 W
1. Gear
2. Gear
1. Gear
2. Gear
Speed (min-1) ............................. 500 ................ 1050 ............ 760 .................. 1570
Drilling diameter (
Ø mm) ............. 62
– 162 ........ 10 – 62 ........ 62 – 200 .......... 10 – 62
Drilling range ..............................
Concrete
max. 132 mm
Masonry
max. 162 mm
......................
......................
Concrete
max. 172 mm
Masonry
max. 200 mm
Weight ........................................ approx. 6,7 kg
approx. 7,0 kg
Speed electronic ......................... yes
yes
Tool fitting .................................................. outer
1.1/4“ UNC, inner G 1/2“
Vibration ..................................... 4,5 m/s2
4,5 m/s2
Drill bit types ............................... SPEED STAR DX, Duramant PRO, EUROLASER, DX-HSP
Personal protection coupling ...................... yes, electronic speed regulation
Typical A-rated sound level:
Noise pressure level (L
pA
) ........... 91 dB (A) ¦ K
pA
3 dB (A)
92 dB (A) ¦ K
pA
3 dB (A)
Sound power level (L
WA
) ............. 102 dB (A) ¦ K
WA
3 dB (A)
103 dB (A) ¦ K
WA
3 dB (A)
The noise level during operation can exceed 85 dB (A). Wear hearing protection!
Measured values determined in accordance with EN 60745-1:2010.
3
Electric supply
Only connect to one-phase alternating current and to the mains voltage indicated on the power
rating plate. Connection is also possible to sockets without earthing contact as this is a
protection class II assembly.
3.1
Putting the PRCD switch into operation
Only suitable for AC current! Note the mains network voltage!
Perform the following test procedure on the PRCD switch before every putting into operation of
the device:
1. Connect the PRCD plug connector with the socket.
2. Press on RESET. The indicator switches to ORANGE (ON).
3. Pull the plug connector out of the socket. The display switches itself off.
4. Repeat 1. and 2.