beautypg.com

ROTHENBERGER RODIADRILL 1800 DWS User Manual

Page 17

background image

ENGLISH

13

Always wear protective goggles when working with the equipment. We recommend protective
gloves, sturdy, non-slip shoes and an apron.

Shavings or chips must not be removed when the equipment is running.

Dust that arises during work is often harmful to health and should not be allowed to enter the
body. Please wear a suitable dust protection mask.

Please remove the plug from the electric socket before all work on the equipment.

Be sure the equipment is switched off before connecting it to the electric socket.

Always keep the connecting cable away from the sphere of action of the equipment. Always
guide the cable away from the equipment to the rear.

Please look out for electric cables, gas and water pipes when working on the wall, ceiling or
floor.

2

Technical Data

1400 DWS

1800 DWS

Nominal acceptance power ......... 2000 W

2500 W

1. Gear

2. Gear

1. Gear

2. Gear

Speed (min-1) ............................. 500 ................ 1050 ............ 760 .................. 1570

Drilling diameter (

Ø mm) ............. 62

– 162 ........ 10 – 62 ........ 62 – 200 .......... 10 – 62

Drilling range ..............................

Concrete

max. 132 mm

Masonry

max. 162 mm

......................

......................

Concrete

max. 172 mm

Masonry

max. 200 mm

Weight ........................................ approx. 6,7 kg

approx. 7,0 kg

Speed electronic ......................... yes

yes

Tool fitting .................................................. outer

1.1/4“ UNC, inner G 1/2“

Vibration ..................................... 4,5 m/s2

4,5 m/s2

Drill bit types ............................... SPEED STAR DX, Duramant PRO, EUROLASER, DX-HSP

Personal protection coupling ...................... yes, electronic speed regulation

Typical A-rated sound level:

Noise pressure level (L

pA

) ........... 91 dB (A) ¦ K

pA

3 dB (A)

92 dB (A) ¦ K

pA

3 dB (A)

Sound power level (L

WA

) ............. 102 dB (A) ¦ K

WA

3 dB (A)

103 dB (A) ¦ K

WA

3 dB (A)

The noise level during operation can exceed 85 dB (A). Wear hearing protection!

Measured values determined in accordance with EN 60745-1:2010.

3

Electric supply

Only connect to one-phase alternating current and to the mains voltage indicated on the power
rating plate. Connection is also possible to sockets without earthing contact as this is a
protection class II assembly.

3.1

Putting the PRCD switch into operation

Only suitable for AC current! Note the mains network voltage!

Perform the following test procedure on the PRCD switch before every putting into operation of
the device:

1. Connect the PRCD plug connector with the socket.

2. Press on RESET. The indicator switches to ORANGE (ON).

3. Pull the plug connector out of the socket. The display switches itself off.

4. Repeat 1. and 2.

This manual is related to the following products: