ROTHENBERGER RODIA DRY CLEANER 1200 User Manual
Page 14
12
ENGLISH
Instantly switch off the appliance if foam or water leaks out. Empty the container and folded filter.
Acids, acetone and solvents can etch appliance parts.
A damaged appliance connecting cable must only be replaced with a special connecting cable
available from the manufacturer or the after-sales service.
2
Technical Data
Rated capacity ............................ 1200 W
Maximum capacity ...................... 1400 W
Frequency .................................. 50 / 60 Hz
Connecting cable ........................ H05VV F 3 x 1,5
Protection class .......................... I
Type of protection ....................... IP 24
Typical A-rated sound level:
Noise pressure level (L
pA
) ........... 69,5 dB (A) ¦ K
pA
3 dB (A)
Sound power level (L
WA
) ............. 80,5 dB (A) ¦ K
WA
3 dB (A)
The noise level during operation can exceed 85 dB (A). Wear hearing protection!
Measured values determined in accordance with EN 61029-1:2010.
3
Function of the Unit
3.1
Overview
(A)
1
Top section
4
Locking bar
10
Wheels
2
Functional plate
5
Lock
11
Steering castors
2a
Rotary switch ON/
OFF/Automatic/Vibration
6
Connecting line
12
13
Filter cassettes
Motor protecion filter
2b
Power socket for electric
tools
7
Container
14
Paper filter bag
(optional accessory)
2c
Volume flow display
8
Suction opening
15
Vacuum hose
3
Cold air inlet
9
Snap-in locks
3.2
Setting into operation
When unpacking, check that the appliance is complete and that there is no transport damage.
Mounting the Vacuum hose
Mount the vacuum hose (15) onto the hose connection piece (8) and turn it in clockwise direc-
tion to the stop.
Electrical equipment
The appliance is switched ON/OFF with the switch (2a) (see fig. A on the top section (1) of the
appliance), or switch to automatic or vibration mode.
0
Suction >off<
I
Suction >on<, (manual operation)
A
Ready for ON/OFF automatic switching system (the vacuum cleaner is switched on and
off by the connected electric tool).
R
Filter cleaning function; in this setting the vibrator will operate for 7 seconds after which it
will be automatically turned off.
AR
Appliance version featuring “AR“ can be operated as described under “A“ except that
automatic
filter cleaning (as described under “R“) is turned on when the volume flow
display lights up.
The power socket (2b) is intended for the connection of an electric tool.