Port status – Axis Communications 231D+/232D+ User Manual
Page 35

35
AXIS 231D+/232D+ - Event Configuration
6. Adjust the Object size, History and Sensitivity profile sliders (see table below for
details). Any detected motion within an active window is then indicated by red
peaks in the Activity window (the active window has a red frame).
7. Click Save.
Please use the online help
for descriptions of each available option.
High
Only very large objects 
trigger motion detection
An object that appears in the region will 
trigger the motion detection for a long 
period
Ordinary colored objects against ordinary 
backgrounds will trigger the motion 
detection
Low
Even very small objects 
trigger motion detection
An object that appears in the region will 
trigger motion detection for only a very 
short period
Only very bright objects against a dark 
background will trigger motion detection
Default values Low
Medium to High
Medium to High
Examples:
• Avoid triggering on small objects in the image by selecting a high
size level.
• To trigger motion detection as long as there is activity in the area, select a high
history level.
• To only detect flashing light, low
sensitivity can be selected. In other cases, a high sensitivity level is
recommended.
Port Status
Under Event Configuration > Port Status there is a list that shows the status for the
connected inputs and outputs of the AXIS 231D+/232D+ for the benefit of the Operator
who cannot access the System Options section.
Example:
If the Normal state for a push button (e.g. doorbell) connected to an input is set to
Open circuit - as
long as the button is not pushed, the state is i
nactive. If the push button is pushed, the state of the input
changes to
active.
If there are parts of the Include window that you wish to exclude, click the 
Configure Excluded Windows radio button and perform steps 1-6 above. 
Click 
Save.
Parameter
Object
Size
History
Sensitivity