Make sure that the hose complies with current
national legislation. The internal diameter of the hose
must measure: 8 mm for liquid gas supply; 13 mm for
methane gas supply.
Once the connection has been performed, make sure
that the hose:
• Does not come into contact with any parts that

reach temperatures of over 50°C.

• Is not subject to any pulling or twisting forces and

that it is not kinked or bent.

• Does not come into contact with blades, sharp

corners or moving parts and that it is not
compressed.

• Is easy to inspect along its whole length so that its

condition may be checked.

• Is shorter than 1500 mm.
• Fits firmly into place at both ends, where it will be

fixed using clamps that comply with current
regulations.

! If one or more of these conditions is not fulfilled or
if the cooker must be installed according to the
conditions listed for class 2 - subclass 1 appliances
(installed between two cupboards), the flexible steel
hose must be used instead (see below).

Connecting a flexible jointless stainless steel pipe to
a threaded attachment
Make sure that the hose and gaskets comply with
current national legislation.
To begin using the hose, remove the hose holder on
the appliance (the gas supply inlet on the appliance
is a cylindrical threaded 1/2 gas male attachment).

! Perform the connection in such a way that the hose
length does not exceed a maximum of 2 metres,
making sure that the hose is not compressed and
does not come into contact with moving parts.
Checking the tightness of the connection
When the installation process is complete, check
the hose fittings for leaks using a soapy solution.
Never use a flame.
Adapting to different types of gas

It is possible to adapt the appliance to a type of gas
other than the default type (this is indicated on the
rating label on the cover).

Adapting the hob

Replacing the nozzles for the

hob burners:

1. Remove the hob grids and

slide the burners off their seats.

2. Unscrew the nozzles using a

7 mm socket spanner (see

figure), and replace them with

nozzles suited to the new type of

gas (see Burner and nozzle specifications table).

3. Replace all the components by following the above

instructions in reverse.

Adjusting the hob burners’ minimum setting:

1. Turn the tap to the minimum position.

2. Remove the knob and adjust the regulatory screw,

which is positioned inside or next to the tap pin, until

the flame is small but steady.

If the appliance is connected to a liquid gas supply,

the regulatory screw must be fastened as tightly as

possible:

3. While the burner is alight, quickly change the position of

the knob from minimum to maximum and vice versa

several times, checking that the flame is not extinguished.

The hob burners do not require primary air adjustment.

After adjusting the appliance so it may be used with a

different type of gas, replace the old rating label with a

new one that corresponds to the new type of gas (these

labels are available from Authorised Technical Assistance

Centres).

Should the gas pressure used be different (or vary

slightly) from the recommended pressure, a suitable

pressure regulator must be fitted to the inlet hose in

accordance with current national regulations relating

to “regulators for channelled gas”.