5.4 Hold-UP Time
The voltage reach down to 2V at CC mode more than 1ms after at AC voltage turned
off.
5.5 Output voltage rise time
The rise time of all outputs voltage shall be less than 500mS measured from 10%
point to 90% point.
5.6 Turn on delay time
3 second maximum from ac input to all outputs within regulation.
6 Environmental Requirement
6.1 Thermal Performance
Operating : 0℃~40℃
Non-operating :-20℃~70℃
6.2 Humidity
Operating : 35% to 85%RH.
Non-operating : 5% to 95%RH.
6.3 Vibration
Operating: 5Hz to 500z sweep at 1.5G constant acceleration for 2 hours on each of
the perpendicular axes x, y and z.
6.4 Power ON/OFF cycling
The power supply shall be designed to withstand a minimum of 10000 on/off cycles
and 3 second on/off period.
6.5 Stress Analysis
All the components have any stress actual not exceed 90 percent.