4 Output Characteristics
4.1 Static Load
Voltage Minimum
load Maximum
load
+5V 0A
1.0A
4.2 Output Voltage
The output voltage shall be statically regulated for all combinations of load, line and
environment including cross regulation as shown.
Voltage Range Tolerance
+5V +4.90V~5.20V ±5%
4.3 Ripple & Noise Voltage
Voltage
5V at full load
Ripple & noise voltage
<100mVp-p
Measuring is done by 20MHz bandwidth oscilloscope and terminated each output with a
10uF capacitor and a 0.1uF capacitor
4.4 Hold-UP Time
10 msec minimum from loss of nominal AC input at full load condition, 110VAC/60Hz
input, output will remain within regulation
4.5 Efficiency
The efficiency (watts out / watts in) is higher than 70% typical while measuring at
nominal line and rated load
4.6 Turn on delay time
During turn on and turn off, no voltage shall exceed its nominal voltage by more than
2% and no output will change its polarity with respect to its return line. All output shall reach
their steady state values within 1 seconds of turn on.