beautypg.com

Spire corp – Spire EON III / SP-AD-090W-EU User Manual

Page 5

background image

Version:A/0 Page 5 of 8

Spire Corp.

Http://www.spirepower.com & Http://www.spirecoolers.com

Http://www.spire-corp.com

The ripple and noise are as follows when measure with Max. Bandwidth of 20MHz and

Parallel 10uF/0.1uF,crossed connected at testing point.

4.5 Hold-UP Time

The voltage reach down to 2V at CC mode more than 1ms after at AC voltage turned

off.

4.6 Output voltage rise time

The rise time of all outputs voltage shall be less than 500mS measured from 10%

point to 90% point.

4.7 Turn on delay time

3 second maximum from ac input to all outputs within regulation.

5 Protection Requirement

5.1 Short Circuit Protection:

The adapter is protected that a short happened between the output terminals and shall

not result in a fire hazard, any damage to this adapter and will be normal operation

automatically while the short is removed.

5.2

Over Voltage Protection

The unit must shutdown when output voltages detect OVP point and the unit shall

not be damaged.

Output Voltage

15V/16V/18V/19V/20V/22V/24V

OVP Point

30VDC

6 Environmental Requirement

6.1 Thermal Performance

Operating : 0℃~40℃

Non-operating :-20℃~70℃

6.2 Humidity

Operating : 20% to 80%RH.

Non-operating : 10% to 90%RH.