7.0 TROUBLESHOOTING
7.1 LOW WATER LEVEL
Proper water level must be maintained within the jacket for the kettle to operate.
Depletion of water may occur from excessive opening of or leakage through the safety
relief valve.
If water is below required operating level, either initially at start-up or during use, the
kettle will automatically shut off and the LOW WATER signal light will come on.
In order for the kettle to operate, the following procedure must be followed:
The kettle must be cool before proceeding with the following steps.
1. Trip the safety relief valve lever to relieve all pressure from the kettle jacket.
2. At exterior rear of kettle jacket remove nut from Air Vent.
3. Insert funnel into Air Vent opening and slowly add the indicated amount of clean
water for:
CAPACITY
ADD:
IF COMPLETELY EMPTY, ADD:
20 gallon kettle
140 ounces
4.14 litres
376 ounces
11.12 litres
30 gallon kettle
150 ounces
4.44 litres
504 ounces
14.90 litres
40 gallon kettle
220 ounces
6.50 litres
548 ounces
16.20 litres
60 gallon kettle
250 ounces
7.39 litres
586 ounces
17.33 litres
80 gallon kettle
340 ounces
10.05 litres
850 ounces
25.12 litres
100 gallon kettle
420 ounces
12.42 litres
1088 ounces
32.17 litres
4. Replace air vent nut.
5. Follow AIR VENTING INSTRUCTIONS below.
6. Continue normal operating procedure of kettle.