1.0 SERVICE CONNECTIONS (Continued) 
 
Installation must conform with local codes, or in the absence of local codes, with the 
National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane 
Installation Code, CSA B149.1, as applicable. 
 
1. The appliance and its individual shut off valve must be disconnected from the gas 
supply piping system during any pressure testing of that system at pressures in 
excess of ½ psi (3.5 kPa). 
 
2. The appliance must be isolated from the gas supply piping system by closing its 
individual manual shut off valve during any pressure testing of the gas supply piping 
system at test pressures equal to or less than ½ psi (3.5 kPa). 
 
Electrical grounding must be provided in accordance with local codes, or in the absence 
of local codes, with the National Electric Code ANS1/NFPA 70, or the Canadian 
Electrical Code, CSA C22.2, as applicable. 
 
Ventilation must be provided in accordance with local codes, or in the absence of local 
codes, with ANSI/SFPA 96 Standard for Ventilation and Fire Protection of Commercial 
cooker Operations. 
 
WARNING: Electrical grounding instructions - units equipped with a 
three-prong (grounding) plug for your protection against shock 
hazard and should be plugged directly into a properly grounded 
three-prong receptacle. Do not cut or remove the grounding prong 
from this plug. (120 volt units only).