6.0 TROUBLESHOOTING
Burners do not come on:
1.
Gas supply to unit is “OFF”.
2.
Manual shut off valve is “OFF”.
3. Thermostat is not tur
ned “ON”.
4. Pan not in lowest position.
5. Ignition control not functioning.
6. Unit electrical supply is not plugged in or turned on.
7. Braising pan has overheated and burners were shut off by high-limit thermostat. Wait
for pan to cool.
Burners produce carbon deposits:
1. Wrong size orifices.
2. Burner air not adjusted properly.
3. Wrong gas supply.
4. Incorrect pressure at supply.