Cleaning and Maintenance

fig. 1

fig.

c. While the Aluminum Mesh Filter frame is out of the unit, the interior of the unit should

be wiped with a soft dry cloth.

6. The UV lamp (fig. 1) is visible looking at the open back side of the main unit after the

Aluminum Mesh Filter has been removed. The UV lamp is removed by rotating it 1/4 turn
and then sliding it out of the top and bottom lamp sockets.

The UV lamp is reinstalled by sliding it into the top and bottom lamp sockets and rotating
it 1/4 turn. The UV lamp should be replaced once a year.

7. The PCO filter (fig. 2) is accessible, when the Aluminum Mesh Filter and UV lamp are out

of the unit. The PCO filter is removed by lifting the tab above the filter and then by pulling
backwards towards the user on the fabric strip at the upper part of the filter. The PCO filter
is reinstalled by fitting the bottom of the filter into its place at the back of the main unit and
then closing the top of the filter until it snaps into place.
The PCO filter should be washed in warm soapy water when replacing the UV lamp.
Make sure that the PCO filter is completely dry before reinstalling it.

8. The Carbon Cord which is the negative ion emitting element is accessible at the front grill

of the unit. The Carbon Cord should be wiped lightly with a soft piece of paper tissue once
every 6 months. The paper tissue should be thrown away after using it.