M. SHUTDOWN INSTRUCTIONS

If the dryer is to be shutdown (taken out of service) for a period of time, the following must be performed:

1. Discontinue power to the dryer either at the external disconnect switch or the circuit breaker.

2. Discontinue the heat supply:

a. GAS MODELS ... discontinue the gas supply.

1) SHUT OFF external gas supply shutoff valve.

L. COMPRESSED AIR REQUIREMENTS

The dryer requires an external supply of compressed air (4.25 cfh @ 80 psi [0.12 cmh @ 5.51 bar]). Compressed air is
necessary/required for blower air jet operation to clean lint from the impellor/fan (squirrel cage).

1. Air Requirements

Shaded areas are stated in metric equivalents

2. Air Regulation

No air regulation or air filtration is provided with the dryer. External regulation/filtration of 80 psi (5.51 bar) must
be
provided. It is suggested that a regulator/filter gauge arrangement be added to the compressed air line just
before the dryer connection. This is necessary to ensure that correct and clean air pressure is achieved.

3. Air Connection

Air connection to this system is a 1/4” quick connection as show in the illustration below.

Compressed

Air Supply

Air Pressure

Normal

80 psi

5.51 bar

Minimum Supply

70 psi

4.82 bar

Maximum Supply

90 psi

6.21 bar