Data pending) – Aquacal H/AT100R User Manual
Page 11
11
Specifications — H/AT100R & 120R Models
Data Plate Nomenclature
1 2 3
4
5
6
7
8 9
10
11
12
A T 1
2
0 A
R A E
W
N
A
CURRENT RELEASED REVISION
A - INITIAL RELEASE
BRAND
H =
HeatWave
OPTIONS
AT= AeroTemp
N-NONE
SB = SouthBeach
TZ = Tropez
CABINET COLOR
W - CRÈME
B - BLACK
CAPACITY
REFRIGERANT
100 = 90000 Btus/hr
120 = 109000 Btus/hr
E - R22
155 = 120000 Btus/hr
T - R407C
Z - R410A
CONTROLS
VOLTAGE
A - ANALOG
A - 1/60/208-230
D - DIGITAL
B - 3/60/208 - 230
D - 3/50/380
H - 1/50/200-220
RFRG CONTROL
H - HEAT
R - REVERSING
100-SERIES:
H100AR
AT100AR
H100BR
AT100BR
H100DR
AT100DR
H100HR
AT100HR
BTU - 80%RH
Air
º
F / Air
º
F… 80/50
88,000/63,000
COP
5.6/4.1
BTU - 63% RH
Air
º
F / Air
º
F… 80/50
83,000/57,000
COP
5.3/3.9
Kilowatt Input (80% RH)
4.6
Voltage/Hz/Phase
208-230/60/1 208-230/60/3 380-415/50/3 220-240/50/1
Min. Circuit Ampacity
38.16 22.13 11.62 26.14
Rec. Fuse or Breaker Size
40 30 15 30
Max. Fuse or Breaker Size
60 35 20 40
Min-Max Water Flow (gpm)
20-70 20-70 20-70 20-70
Shipping weight (lbs)
320 320 320 320
Shipping Size (LXW XH)
36” X 40” X 43"
36” X 40” X 43"
36” X 40” X 43"
36” X 40” X 43"
Uncrated Weight
293 293 293 293
120-SERIES:
H120AR
AT120AR
H120BR
AT120BR
H120DR
AT120DR
H120HR
AT120HR
BTU - 80%RH
Air
º
F / Air
º
F… 80/50
103,000/70,000
COP
5.4/4.1
BTU - 63% RH
Air
º
F / Air
º
F… 80/50
99,000/68,000
COP
5/3.8
Kilowatt Input (80% RH)
5.6
Voltage/Hz/Phase
208-230/60/1 208-230/60/3 380-415/50/3 220-240/50/1
Min. Circuit Ampacity
38.16 26.14 12.82 36.56
Rec. Fuse or Breaker Size
40 30 15 40
Max. Fuse or Breaker Size
60 40 20 60
Min-Max Water Flow (gpm)
20-70 20-70 20-70 20-70
Shipping weight (lbs)
330 330 330 330
Shipping Size (LXW XH)
36” X 40” X 43"
36” X 40” X 43"
36” X 40” X 43"
36” X 40” X 43"
Uncrated Weight
303 303 303 303
(DATA PENDING)
(DATA PENDING)