Installation, Warning, Ph control installation – Aquacal Pool Pilot 75003 User Manual

Page 28: Plumbing

background image

INSTALLATION

22

Optional Tap Points

For

Digital TC

Total Control

Acid In




Water Out

Tap Point
Locations

Always Insert tubing
into appropriate
inlet/outlet.

See Digital TC manual
for drilling instructions.

Stenner

Acid Pump

and Tank

Kit

pH Control Installation

Plumbing

Have these tools on hand prior to starting this step:

• Drill

• 1/2” standard drill bit (or 1/4” NPT bit and tap if using Stenner

components)

• Utility knife


A hole must be drilled into the manifold assembly for installation of the
injector fitting for the Muriatic Acid.

1. Locate the Acid Feed Pump and tank within proper cord

distances to the Pool Chemistry Controller System and Power source.

2. Turn the pump off, disconnect the cell and tri-sensor cords,

and remove the manifold piping (without the cell) to a clean
working area. See diagram for which unions to remove (marked

➀in diagram above).

3. Locate the label on the manifold assembly marked “Optional Tap Points” (marked

② in diagram above), and drill the

appropriate mounting hole adjacent to where indicated on the label marked “Acid In”. Do not drill through the label!
Use a drill stop attachment if available, or wrap a piece of masking tape, exposing 1” of the tip of the drill bit as a stop
indicator. This will prevent drilling through the far side of the PVC, damaging the manifold.

Note: Use care to drill the hole perpendicular and deburr, for a leak-free connection of the injector fitting.
Do not over drill or ream the hole as oversized holes will leak and are not covered under warranty.

Follow steps #4 and 5 if using AutoPilot factory components or skip to #6 if using Stenner factory components

4. Insert the black injector fitting (Uniseal) into the ½” hole.

Note: Do not use any lubrication or sealing compounds!

5.

Insert the one-direction check valve assembly into the Uniseal, and then insert the AutoPilot supplied
black plastic tubing (marked 1/8” ID x ¼” OD) onto the check valve. Ensure the tubing is square
edged before inserting (use the utility knife to cut if needed).
Note: If it seems too tight, use some water or dishwashing detergent. Do not use any other lubricants!

6. IF USING THE STENNER FACTORY COMPONENTS, FOLLOW THE INSTRUCTIONS IN THE

STENNER INSTALLATION MANUAL AND USE ALL STENNER SUPPLIED TUBING
AND FITTINGS as AutoPilot and Stenner factory tubing and fittings are not
interchangeable.

7. If the acid collection tube has not already been installed, do so at this time.

This will connect to the closer fitting on the Stenner head assembly.

8. Roll out the tubing to connect into the Acid Feed Pump, again ensuring a squared edge.

Leave enough slack in the tubing to secure the tubing with ty-wraps.

! Warning

Avoid any sharp bends and over tightening the Ty-Wrap to the
tubing, which can hinder proper flow of the chemicals

9. Remove the tank access lid and adjust the Stenner acid tank

tubing weight so that it is about 1/2” (1.5 cm) from the bottom

of the tank.

10. Add 1 – 2 gallons of water into the acid tank.

STOP! At this point, turn on the circulation pump and perform the
“Prime Acid Pump”, see pg. 35, and check for any leaks in the acid
tubing and fittings.

11. Once secured and adjusted, continue adding water and muriatic acid

into the tank for a recommended acid mixture of 4 parts water to 1 part
muriatic acid dilution.



! Warning

To avoid damaging splashes, ALWAYS ADD
ACID TO WATER, never water to acid.

Optional Tap

Points

For

Digital TC

Total Control

Acid In






Water
Out

Tap Point
Locations

Always Insert tubing
into appropriate
inlet/outlet.
See Digital TC
manual