2. Technical Gas Data

a. Gas Specifications

* Measured at the gas valve pressure tap when the gas valve is on.

b. Gas Connections

Inlet connection -------- 3/4” N.P.T.
Inlet supply size -------- 3/4” N.P.T. (minimum)
Btu/hr input -------------- 204,000 (51,408 kcal/hr)

1) Natural Gas

Regulation is controlled by the dryer’s gas valve’s internal regulator. Incoming supply pressure
must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches
(29.9 mb) water column (W.C.) pressure.

2) Liquid Propane (L.P.) Gas

Dryers made for use with L.P. gas have the gas valve’s internal pressure regulator blocked open so
that the gas pressure must be regulated upstream of the dryer. The pressure measured at each
gas valve pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no
regulator or regulation provided in an L.P. dryer. The water column pressure must be regulated at
the source (L.P. tank) or an external regulator must be added to each dryer.

* Drill Material Size (D.M.S.) equivalents are as follows:
Natural Gas .................. #23 = 0.1540” (3.9116 mm).
L.P. Gas ........................ #42 = 0.0935” (2.3749 mm).

TYPE OF GAS

NATURAL

LIQUID PROPANE

Manifold Pressure*

3.5 inches W.C.

8.7 mb

10.5 inches W.C.

26.1 mb

In-Line Pressure

6.0 - 12.0 inches W.C.

14.92 - 29.9 mb

11.0 inches W.C.

27.4 mb

Shaded areas are stated in metric equivalents

TYPE OF GAS

Liquid Propane

Conversion Kit

Part Number

MODEL

NUMBER

BTU

Per Hour

Rating

kcal/hr

Rating

Natural

Liquid Propane

Qty.

D.M.S.*

Part

Number

Qty.

D.M.S.*

Part

Number

D-78

204,000

51,408

3

#23

140856

3

#42

140810

883298

Shaded area is stated in metric equivalent