beautypg.com

Burner and nozzle characteristics – Ariston K3G21/G User Manual

Page 7

background image

7

Pay particular attention to the plug wires and
thermocouple tubes.

Important
On completion of the operation, replace the old rating
sticker with one indicating the new type of gas used. This
sticker is available from our Service Centres.

Note
Should the pressure of the gas used be different (or vary)
from the recommended pressure, it is necessary to fit a
suitable pressure regulator onto the inlet pipe in compliance
with current National Regulations relative to “regulators
for channelled gas”.

*

At 15°C and 1013 mbar- dry gas

**

Propane

P.C.S. = 50,37 MJ/Kg

***

Butane

P.C.S. = 49,47 MJ/Kg

Natural

P.C.S. = 37,78 MJ/m

3

Burner and nozzle characteristics

Table 1

Liquid Gas

Natural Gas

Burner

Diameter

(mm)

Thermal Power

kW (p.c.s.*)

By-Pass

1/100

Nozzle

1/100

Flow*

g/h

Nozzle

1/100

Flow*

l/h

Nominal

Reduced

(mm)

(mm)

***

**

(mm)

Fast
(Large)(R)

100

3.00

0.7

41

87

218

214

128

286

Semi Fast
(Medium)(S)

75

1.90

0.4

30

70

138

136

104

181

Auxiliary

(Small)(A)

51

1.00

0.4

30

52

73

71

76

95

Oven

-

3.10

1.0

46

85

225

221

132

295

Grill

-

2.50

-

-

80

182

179

122

227

Supply

Pressures

Nominal (mbar)

Minimum (mbar)

Maximum (mbar)

28-30

20
35

37
25
45

20

17

25

K3G2/G
K3G21/G

S S

R

A

This manual is related to the following products: