beautypg.com

Wiring diagrams – Aprilaire 8355 User Manual

Page 11

background image

11

R

Y1

O

B

G

E

W2

L

C

Y2

APRILAIRE MODEL 8355 HEAT PUMP THERMOSTAT

R

Y

O

G

E

W2

L

C

W3

CARRIER LOW VOLTAGE TERMINAL BOARD

APRILAIRE MODEL 8355 HEAT PUMP THERMOSTAT CONVERSION TO CARRIER

SPLIT SYSTEM CONDENSORS AND HEAT PUMP SYSTEMS

THE LOW VOLTAGE TERMINAL DESIGNATIONS AND THEIR DESCRIPTION AND/OR

FUNCTION ARE USED ON ALL SPLIT SYSTEM CONDENSORS AND HEAT PUMPS

24 VAC, RETURN

COMPRESSOR CONTACTOR

REVERSING VALVE [COOLING MODE]

FAN CONTACTOR CIRCUIT

EMERGENCY HEATING CIRCUIT

2ND. STAGE HEATING CIRCUIT

SYSTEM MONITOR LED

24 VAC, COMMON

R

Y1

O

B

G

E

W2

L

C

Y2

APRILAIRE MODEL 8355 HEAT PUMP THERMOSTAT

R

Y

B

G

E

W2

L

X

O

COLEMAN LOW VOLTAGE TERMINAL BOARD

APRILAIRE MODEL 8355 HEAT PUMP THERMOSTAT CONVERSION TO

ROBERT SHAW 3000 SERIES HEAT PUMP SYSTEMS

THE LOW VOLTAGE TERMINAL DESIGNATIONS AND THEIR DESCRIPTION AND/OR

FUNCTION ARE USED ON ALL SPLIT SYSTEM CONDENSORS AND HEAT PUMPS

24 VAC, RETURN

COMPRESSOR CONTACTOR

REVERSING VALVE [HEATING MODE]

FAN CONTACTOR CIRCUIT

EMERGENCY HEATING CIRCUIT

2ND. STAGE HEATING CIRCUIT

SYSTEM MONITOR LED

24 VAC, COMMON

Wiring Diagrams

The following is just a sample of the most common types of HVAC systems.
Refer to your system’s installation manual for wiring information.