Environmental requirement – Alloy Computer Products GL242201 User Manual
Page 5

5
Link Quality
Receiving AP link quality on infrastructure networking mode
Signal Strength
Receiving AP signal strength on infrastructure networking mode
5. REGULATION COMPLIANCE
Compliant with
FCC Part 15 Class B and C
ETSI EN 300 328-2 and ETSI EN 301 489-1, -17, EN60950, CE-Mark
Telec (Japan, Customized)
WiFi
Compliant
6. Environmental Requirement
6.1. Drop and Vibration
6.1.1. Anti-Static Voltage
Static voltage tests by 4 kV in card frame should not cause system fail
6.1.2. Vibration Test
The vibration test is under the frequency and amplitude 10-25 Hz 1mm in vertical and horizontal direction by 30
minutes that should not cause any damage on product
.
6.1.3. Package Drop Test
Dropping the package from the height of 50cm for each of the six(6) faces onto the hard-wood floor should not cause
any damage on product.
6.2. Operation Environment
6.2.1.
Temperature
Range
Operating:
-0℃ - +55℃ (Except RF output power and sensitivity)
Storage:
-20℃ - +70℃
6.2.2.
Reliability
Test
One cycle of reliability test is keeping at -30℃ by 2 hours, switching temperature up to +60℃ within one hour , and
testing at +60℃ by 2 hours, and switching temperature to -30℃ within one hour. Three cycle should be tested and
without any product fail.
6.2.3.
Humidity
Operating:
0% to 70%