5

Link Quality

Receiving AP link quality on infrastructure networking mode

Signal Strength

Receiving AP signal strength on infrastructure networking mode

5. REGULATION COMPLIANCE

Compliant with

FCC Part 15 Class B and C

ETSI EN 300 328-2 and ETSI EN 301 489-1, -17, EN60950, CE-Mark

Telec (Japan, Customized)

WiFi

Compliant

6. Environmental Requirement

6.1. Drop and Vibration

6.1.1. Anti-Static Voltage

Static voltage tests by 4 kV in card frame should not cause system fail

6.1.2. Vibration Test

The vibration test is under the frequency and amplitude 10-25 Hz 1mm in vertical and horizontal direction by 30

minutes that should not cause any damage on product

.

6.1.3. Package Drop Test

Dropping the package from the height of 50cm for each of the six(6) faces onto the hard-wood floor should not cause

any damage on product.

6.2. Operation Environment

6.2.1.

Temperature

Range

Operating:

-0℃ - +55℃ (Except RF output power and sensitivity)

Storage:

-20℃ - +70℃

6.2.2.

Reliability

Test

One cycle of reliability test is keeping at -30℃ by 2 hours, switching temperature up to +60℃ within one hour , and

testing at +60℃ by 2 hours, and switching temperature to -30℃ within one hour. Three cycle should be tested and

without any product fail.

6.2.3.

Humidity

Operating:

0% to 70%