Maintenance – Campbell Scientific SR50A Distance Sensor User Manual
Page 25

SR50A Sonic Ranging Sensor
FIGURE 6. SR50A - Mounted using a NU-RAIL Fitting and
19484 Mounting Stem
SR50A with 6-plate gill radiation shield – the picture below shows the
SR50A stem attachment
5. Maintenance
The SR50A’s electrostatic transducer requires equal pressure on both sides. 
Vent holes in the transducer housing are used to equalize pressure. Desiccant 
is placed inside the transducer housing to prevent the possibility of condensing 
humidity. The desiccant must be inspected and, if required, replaced on a 
regular basis. The desiccant supplied with the SR50A uses an indicating silica 
gel and will remain blue if it is still capable of absorbing moisture. Once the 
desiccant becomes saturated the color will change from blue to pink. If the 
SR50A is used in humid environments, the desiccant should be replaced more 
frequently. To inspect or replace the desiccant, follow the procedures outlined 
in Section 6 under disassembly. 
The five small desiccant packets used in the transducer housing are part 
number 4091. 
19