4. Maintenance

An occasional cleaning of the glass improves the solar panel’s efficiency. If a
problem with the solar panel is suspected, the panel may be checked by
measuring the voltage output. Check the voltage with a voltmeter connected
between the two leads of the solar panel. There must be incident solar
radiation on the panel and there must be a load connected to the solar panel.
The load can be the datalogger, other equipment, or a 75 ohm resistor capable
of dissipating solar panel power between the two leads. No voltage output
implies a bad solar panel, regulator, or cable. The magnitude of the voltage
output depends on the incident solar radiation.