beautypg.com

Campbell Scientific SDM-SIO4 4-Channel Serial I/O Interface User Manual

Page 74

background image

Section 6. Data Error Detection

6-12

is for a number with ten digits – if the number is less than this the 1.125ms
figure would reduce by 0.1ms per digit.

1

8 bit binary

0.155ms

2,3

16 bit binary

0.216ms

4,5

32 bit binary

0.334ms

6

ASCII decimal

1.125ms

7

8 bit ASCII hex

0.226ms

8

16 bit ASCII hex

0.355ms

9

32 bit ASCII hex

0.613ms

The above timings are preliminary.

d

With the CRC32 and CRC16-CCITT there is a extra 0.19ms for an additional
calculation. This is required as part of the CRC algorithm.

The total extra processing time above the SDM-SIO4’s normal delays is
calculated by the following:

Total time in µsec needed before the next P113 is started =

a+(one from b)+(one from c)+(d if applicable)+any other delays
required by the format command