Campbell Scientific SDM-SIO4 4-Channel Serial I/O Interface User Manual
Page 74
Section 6. Data Error Detection
6-12
is for a number with ten digits – if the number is less than this the 1.125ms
figure would reduce by 0.1ms per digit.
1
8 bit binary
0.155ms
2,3
16 bit binary
0.216ms
4,5
32 bit binary
0.334ms
6
ASCII decimal
1.125ms
7
8 bit ASCII hex
0.226ms
8
16 bit ASCII hex
0.355ms
9
32 bit ASCII hex
0.613ms
The above timings are preliminary.
d
With the CRC32 and CRC16-CCITT there is a extra 0.19ms for an additional
calculation. This is required as part of the CRC algorithm.
The total extra processing time above the SDM-SIO4’s normal delays is
calculated by the following:
Total time in µsec needed before the next P113 is started =
a+(one from b)+(one from c)+(d if applicable)+any other delays
required by the format command