Campbell Scientific SAT ARGOS Argos Transmitter User Manual
Page 12

SAT ARGOS
6
; Load more values in input locations
2: Bulk Load (P65)
1:
99
F
2:
101
F
3:
102
F
4:
103
F
5:
104
F
6:
105
F
7:
106
F
8:
107
F
9:
11
Loc [ Start_9 ]
; If top of the hour, write 16 data point to FS1
3: If time is (P92)
1:
0
Minutes (Seconds --) into a
2:
60
Interval (same units as above)
3:
10
Set Output Flag High (Flag 0)
4: Real Time (P77)
1:
1220
Year,Day,Hour/Minute (midnight = 2400)
5: Sample (P70)
1:
13
Reps
2:
3
Loc [ Start_1 ]
; If top of the hour, transfer all new data to the SAT ARGOS transmitter
6: If time is (P92)
1:
0
Minutes (Seconds --) into a
2:
60
Interval (same units as above)
3:
30
Then Do
7: SCD2/ARGOS (P125)
1:
19
Return Code Loc [ R_Code ]
8: End (P95)
; Check result of P125, if greater than 1 execute P125 again
9: If (X<=>F) (P89)
1:
19
X Loc [ R_Code ]
2:
3
>=
3:
2
F
4:
30
Then Do
10: SCD2/ARGOS (P125)
1:
19
Return Code Loc [ R_Code ]
11: End (P95)
*Table 2 Program
02: 0.0000
Execution Interval (seconds)
*Table 3 Subroutines
End Program