PS12LA, PS512M, CH12R, CH512R Power Supplies and Charging Regulators

2

3. Wiring

An internal or external battery is connected to the charger by means of the INT
(Internal) or EXT (External) connectors, as shown in Figure 1. An “external
battery” cable comes with the charger that allows connecting another battery to
the charger to provide power if the main battery is removed. The red lead
connects to the positive battery terminal and the black lead connects to the
negative terminal.

Reversal of polarity of external battery will damage the
PS12LA or PS512M.

It is possible to leave two batteries connected. The battery connections are
diode isolated (Figure 3-2); however, if one of the batteries fail, it could draw
all the charging current and the other battery will be discharged.

A battery must be attached for the charger to function
correctly as a power supply.

The leads from the transformer or solar panel are connected to the CHG
terminals. Polarity does not matter; either lead can be connected to either
terminal.

The wires that connect power to the datalogger and/or peripherals are
connected to the +12 and ground ( ) terminals.

INT

EXT

BATT

CHG

OFF

ON

CHG

CHG

+12

+12

FIGURE 1. Wiring to Charger

WARNING

CAUTION

To Battery

From Transformer or Solar Panel

{

To Datalogger or peripherals

{

These look identical

when unplugged