Wiring, Example programs – Campbell Scientific HMP50 Temperature and Relative Humidity Sensor User Manual
Page 10

HMP50 Temperature and Relative Humidity Probe
Black Temperature
Signal
White
Relative Humidity Signal
Blue
Signal & Power Reference
Brown
Power
Clear Shield
FIGURE 5. HMP50 Wiring
TABLE 2. Datalogger Connections
Wire Label
Color
CR800, CR3000,
CR200, CR23X,
CR1000
CR10(X), CR510
21X, CR7
Temp Signal
Black
Single-Ended Input
Single-Ended Input
Single-Ended Input
RH Signal
White
Single-Ended Input
Single-Ended Input
Single-Ended Input
Power & Signal
Ground
Blue G
G
Power 12V
Brown
12 V
12 V
12 V
Shield Clear
G
4. Wiring
Connections to Campbell Scientific dataloggers are given in Table 2. The
probe is measured by two single-ended analog input channels, one for
temperature and one for relative humidity.
Always connect the Blue lead to the datalogger first,
followed by the Black, White, and Clear leads. Connect
the Brown (Power) lead last.
CAUTION
5. Example Programs
This section is for users who write their own datalogger programs. A
datalogger program to measure this sensor can be created using Campbell
Scientific’s Short Cut Program Builder Software. You do not need to read this
section to use Short Cut.
6