Campbell Scientific CS210 (10162) Enclosure Humidity Sensor User Manual

Page 8

background image

CS210 Enclosure Humidity Sensor

'Define Data Tables
DataTable (Daily,1,-1)
DataInterval

(0,1,Day,10)

Minimum

(1,Batt_Volt,FP2,0,False)

Minimum

(1,PanelTempC,FP2,False,False)

Maximum

(1,PanelTempC,FP2,False,False)

Maximum

(1,Enc_RH,FP2,False,False)

EndTable

'Main Program
BeginProg
Scan

(10,Sec,0,0)

PanelTemp

(PanelTempC,250)

Battery

(Batt_volt)

'Measure CS210. Sensor is on all the time. Don't need a delay.

VoltSe

(Enc_RH,1,mV2500,1,1,0,250,0.1,0)

'Set the sensor to 100% if it exceeds 100%.

If Enc_RH > 100 Then Enc_RH = 100

CallTable

Daily

NextScan
EndProg

Example 2. Sample CR200 Program

'CR200 Series Datalogger
'To create a different opening program template, type in new
'instructions and select Template | Save as Default Template
'date:
'program author:

'SENSOR WIRING
'CS210
'Black: C2
'White: SE1
'Clear: G

'Declare Public Variables
'Example:
Public batt_volt
Public Enc_RH

'Define Data Tables
DataTable (Daily,1,-1)
DataInterval

(0,24,hr)

Minimum

(1,batt_volt,0,0)

Maximum

(1,Enc_RH,False,0)

EndTable