Samlex America Steca_Solarix_PRS User Manual
Page 8

Load cannot be
operated
+
info LED flashes
red
+
. green LED
flashes
load output is switched off
due to excessive battery
voltage
•
the load output automatically
switched on again as soon as
the battery voltage lies within
the permissible range
incorrect grounding
•
check the grounding
external charging source is
not voltage-limited
•
check the external charging
source
if necessary, switch off exter-
nal charging sources
Load cannot be
operated
+
info LED illumi-
nates green
defective load or installation
error
•
connect load correctly
replace load
Battery is not
charged
solar module not connected
•
connect the solar module
solar module connected with
incorrect polarity
•
connect the solar module
with the correct polarity
short circuit at solar module
input
•
correct the cause of the short
circuit
incorrect solar module
voltage
•
use a solar module of the
specified voltage
solar module defective
•
replace the solar module
Battery display
jumps quickly
large pulse current
•
tune the current consump-
tion to match the battery
capacity
battery is defective
•
replace the battery