SPECIFICATIONS


CAUTION! : THERE IS NO ISOLATION BETWEEN THE INPUT AND THE OUTPUT.
INPUT AND OUTPUT HAVE A COMMON NEGATIVE

Input to output isolation

Not isolated. Input and output connections have a common negative

Input voltage

20 to 35 VDC

Output voltage

13.8 VDC ± 0.1 V

Output voltage regulation

Less than 3%

Input current at no load

50 mA

Output current
Continuous 60

A

Current limit *

70 A


*Note: In current limit condition, the output voltage will drop if the

current drawn increases beyond the current limit value of 70 A


Output ripple and noise

less than 50 mV RMS

Efficiency

Approx.

92%

Operating ambient temperature -

-20 to +30

o

C (derate linearly to zero at 70º C)

Humidity

Max.

95%,

non

condensing

Protections:
-

Overload

By

current

limiting

-

Cooling

Temperature

controlled

fans

- Over heating

Drop in output voltage

- Reverse polarity

Fuse protection

- Over voltage

Varistor (also protects against load dump)

Input side fuses

60 A (2 pieces of 32V, 30A in parallel)

Safety and EMC Standards:
-

Emission

EN50081-1

-

Immunity EN50082-1

- Automotive directive

95/45/EC

Input / output connections

Terminal Block - M6 Bolt and Nut

Weight

2.6 lbs / 1.2 Kg

Dimensions (H x W x D)

3.5” x 3.6” x 7” / 90 x 93 x 177mm

Warranty

2

years


NOTE: Specifications are subject to change without notice

Samlex America Inc.

110-17 Fawcett Road

Coquitlam BC Canada V3K 6V2

Telephone: (604) 525-3836

SDC60-August2006