Programming Procedure: Brightness of lED Display:
The unit comes
preset with brightness of the LEDs set at Normal (Bright). The brightness can be dimmed or
the LEDs can be switched OFF. Settings can be changed with the help of the Programming
Button (5, Fig 1). Settings are performed in sequential order in a loop: Bright » Dim » OFF
» Bright » Dim » OFF… repeats the loop.
For changing the Setting: Press and hold Programming Button » Beep will be heard
» Release the Button.
Please note that when the LED display is switched OFF, the Buzzer alarm protocols stay
active in the background. Hence, if Under Voltage / Over Voltage condition is activated,
the LED display and Buzzer alarm protocols for the abnormal condition will be activated.
Programming Procedure: Alarm Thresholds / 3-Day Timer
Thresholds of Low Voltage / High Voltage Alarms and Timer ON / OFF settings are
programmed with the help of Programming Button (5, Fig 1) and by monitoring the LED
and Buzzer indication patterns. CAuTION! Alarm thresholds are to be programmed
only when the voltage is between 10.5V and 13.3V (for 12V battery) and between
21V and 26.6V (for 24V battery). In this condition, the lEDs / Buzzer should not
be indicating “charging” i.e., should not be displaying “Walking lEDs – Fast” or
“Walking lEDs – Slow.”
Programming Modes are SEQUENTIAL as shown in the sequence given below. This means
that in order to access programming of the desired parameter, it will be necessary to pass
through the previous programming positions. Press Programming Button (5, Fig 1) and
hold it in pressed condition. Release the Button ONLY when the LED + Beeping pattern for
the desired parameter is displayed.
The sequence starts with Programming Mode for Low Voltage Thresholds first followed by
High Voltage Thresholds and then followed by Timer ON/OFF. Before the start of each
Programming Mode, all the 3 LEDs and buzzer will blink simultaneously 3 times.
To START, press Programming Button (5, Fig 1) and hold it in pressed condition. Release
the Button ONLY when the LED + Beeping pattern for the desired parameter is
displayed.
» long beep » {(Red+Yellow+Green+Beep) » (Red+Yellow+Green+Beep)}…
3 Times (low Voltage Threshold Programming Menu starts)
lOW VOlTAGE MENu STARTS
12V Battery
24V battery
(Red + Beep) - 3 blinks
10.5V (Preset)
21V (Preset)
(Red + Beep) - Steady
10.6
21.2
(Red + Yellow + Beep) - 3 Blinks
10.7V
21.5V
(Red + Yellow + Beep) - Steady
10.8V
21.6V
(Yellow + Beep) - 3 Blinks
10.9V
21.8V
(Yellow + Beep) - Steady
11.0V
22.0V
(Yellow + Green + Beep) - 3 Blinks
11.1V
22.2V
(Yellow + Green + Beep) - Steady
11.2V
22.4V
{(Red+Yellow+Green+Beep) » (Red+Yellow+Green+Beep)}… 3Times
(High Voltage Threshold Programming Menu starts)
HIGH VOlTAGE MENu STARTS
12V Battery
24V battery
St
eady Red + Long Beep
14.8V
29.6V
Steady Yellow + Long Beep
15.3V
30.6V
Steady Green + Long Beep
16.0V
32.0V
long Pause
(3-Day timer Programming Menu Starts)
3 DAY TIMER ACTIVATION
Short B
eep (No LED)
3-Day Timer ON
Long Pause
3 DAY TIMER DE-ACTIVATION
Long Beep (No LED)
3-Day Timer OFF
Programming sequence ends. Release Programming Button
Specifications
Battery System Voltage ............................ 12V / 24V (Auto Detection)
Input voltage Range ...............................................7 VDC to 32 VDC
Input current ........................................................... Less than 30 mA
Battery Input Connectors .......¼” / 6.3 mm Male Quick Connect Tabs
Input Wiring .............................................................AWG # 22 to 26
Fuse* .........................................................................................0.5A
Dimensions, mm..........................................................65 x 65 x 25.5
Weight .................................................................................... 35 gm
* In series with Positive wire preferably within 7” from the Battery Positive
2 YEAR lIMITED WARRANTY
Battery Monitor BW-01 manufactured by Samlex America, Inc. (the “Warrantor“) is
warranted to be free from defects in workmanship and materials under normal use and
service. The warranty period is 2 years for the United States and Canada, and is in effect
from the date of purchase by the user (the “Purchaser“).
Warranty outside of the United States and Canada is limited to 6 months. For a warranty
claim, the Purchaser should contact the place of purchase to obtain a Return Authorization
Number.
The defective part or unit should be returned at the Purchaser’s expense to the authorized
location. A written statement describing the nature of the defect, the date of purchase,
the place of purchase, and the Purchaser’s name, address and telephone number should
also be included.
If upon the Warrantor’s examination, the defect proves to be the result of defective
material or workmanship, the equipment will be repaired or replaced at the Warrantor’s
option without charge, and returned to the Purchaser at the Warrantor’s expense.
(Contiguous US and Canada only)
No refund of the purchase price will be granted to the Purchaser, unless the Warrantor is
unable to remedy the defect after having a reasonable number of opportunities to do so.
Warranty service shall be performed only by the Warrantor. Any attempt to remedy the
defect by anyone other than the Warrantor shall render this warranty void. There shall be
no warranty for defects or damages caused by faulty installation or hook-up, abuse or
misuse of the equipment including exposure to excessive heat, salt or fresh water spray, or
water immersion.
No other express warranty is hereby given and there are no warranties which extend
beyond those described herein. This warranty is expressly in lieu of any other expressed
or implied warranties, including any implied warranty of merchantability, fitness for the
ordinary purposes for which such goods are used, or fitness for a particular purpose, or
any other obligations on the part of the Warrantor or its employees and representatives.
There shall be no responsibility or liability whatsoever on the part of the
Warrantor or its employees and representatives for injury to any persons, or damage
to person or persons, or damage to property, or loss of income or profit, or any other
consequential or resulting damage which may be claimed to have been incurred
through the use or sale of the equipment, including any possible failure of malfunction
of the equipment, or part thereof. The Warrantor assumes no liability for incidental or
consequential damages of any kind.
Samlex America Inc. (the “Warrantor”)
www.samlexamerica.com
DETAIlED PRODuCT INFORMATION
For a complete user manual including specifications, application notes, installation
instructions, trouble shooting and more, please visit the web page for this product on
www.samlexamerica.com. Product page can be found using the “Search by Model”
field.
11004-BW-01-1213