4. Troubleshooting

WARNING!

Do not open or disassemble the S600 Inverter.
Attempting to service the unit yourself may cause an
electrical shock or fire.

Problems and Symptoms

Possible Cause

Solutions

Low output voltage

Using average reading

Use true RMS reading

meter and cable.

(110V:

1

95-105VAC,

Voltmeter.

(

220V:190-210VAC)

See page 11

3-4-7. of the manual

Load LED bar flash.

Overload Reduce

load.

No output voltage

Low input voltage.

Recharge battery,

Voltage indicator

check connections

In the lower red zone

and cables.

No output voltage.

Thermal shutdown

Improve

ventilation,

Over Temp indicator on

make sure ventilation

shafts of the inverter

Load less than 600W

are not obstructed.

Lower

ambient

temperature.

No output voltage

Short circuit or Wiring

Check AC wiring

Overload indicator on

error.

for short circuit or

improper

polarity

(hot

and neutral reversed).

Very high power load

Remove load.