4. Troubleshooting:
WARNING!
Do not open or disassemble the S600 Inverter.
Attempting to service the unit yourself may cause an
electrical shock or fire.
Problems and Symptoms
Possible Cause
Solutions
Low output voltage
Using average reading
Use true RMS reading
meter and cable.
(110V:
1
95-105VAC,
Voltmeter.
(
220V:190-210VAC)
See page 11
3-4-7. of the manual
Load LED bar flash.
Overload Reduce
load.
No output voltage
Low input voltage.
Recharge battery,
Voltage indicator
check connections
In the lower red zone
and cables.
No output voltage.
Thermal shutdown
Improve
ventilation,
Over Temp indicator on
make sure ventilation
shafts of the inverter
Load less than 600W
are not obstructed.
Lower
ambient
temperature.
No output voltage
Short circuit or Wiring
Check AC wiring
Overload indicator on
error.
for short circuit or
improper
polarity
(hot
and neutral reversed).
Very high power load
Remove load.