Adjustment of the Hygrometer
Initial adjustment of the hygrometer is not necessary. However, to maintain
accuracy, it is recommended that hygrometers be kept in permanently low
humidity areas (i.e., central heating/air conditioning, etc.) wrapped in a damp
cloth for 24 hours to reactivate “lazy” dried out coils. After the 24 hour period,
the scale should read approximately 95%. Repeat this procedure every three
to four months for best performance.
Hygrometer Specifications:
Range: 20-90% RH
Tolerance: +/- 9%
14
This manual is related to the following products:
- Endurance II 105 Thermometer Chrome Endurance 125 Comfortmeter Endurance 145 Barometer/Comfortmeter Endurance 085 Comfortmeter Endurance II 105 Comfortmeter Endurance II 135 Comfortmeter Endurance II 115 Comfortmeter Endurance II 135 Chrome Open Dial Barometer Endurance II 105 Chrome Open Dial Barometer Endurance II 135 Open Dial Barometer Endurance II 115 Barometer/Thermometer Endurance II 115 Open Dial Barometer Endurance II 105 Open Dial Barometer