beautypg.com

Accessories – Siemens 27 Electric Dryer User Manual

Page 8

background image

8

2 ć Exhaust air outlet on the side (optional)

3 ć Exhaust air outlet on the underside of the

appliance (optional)

Special exhaust air connections must

be obtained from your dealer or part

supplier for either connection type (see

page 8).
-

Side exhaust kit

-

Bottom exhaust kit

A qualified technician should change

the exhaust air outlet to the optional

connection location.

Ductwork

To ensure optimum performance, the

ducting system of the dryer should be

as short as possible with a minimum

number of elbows. Your dryer will work

best when the venting system has as

few air flow restrictions as possible.

Exhaust ducting which is longer than

recommended may extend drying time,

cause lint to accumulate and affect

dryer performance and dryer lifeĆtime.
FourĆinch (approx. 100 mm) diameter

ducting should be used. Use either

rigid metal or flexible metal ducting

material.

DO NOT

use plastic or nonĆmetal duct

with this dryer.
DO NOT assemble the ductwork with

screws or fasteners that extend into the

duct. They will serve as an

accumulation point for lint.

Joints should be secured with

aluminum tape.

All joints should be tight to avoid leaks.

The male end of each duct section

must point away from the dryer.

Whether connecting to an existing

venting system or a new venting

system, make sure that all ducting is

clean and free of lint.
The maximum permitted length for both

rigid and flexible metal duct is shown in

the table below.

Number of
90° Turns
or Elbows

Rigid Duct

Flexible Duct

0

66 ft.

(2011 cm)

45 ft.

(1372 cm)

1

56 ft.
(1707 cm)

36 ft.
(1097 cm)

2

48 ft.
(1463 cm)

29 ft.
(884 cm)

3

39 ft.
(1189 cm)

22 ft.
(671 cm)

4

30 ft.
(914 cm)

16 ft.
(488 cm)

Note:

Side and bottom exhaust installations

have a 90° turn inside the dryer. To

determine maximum exhaust length,

add one 90° turn to the chart.
More than two 90

°

turns are not

recommended. For best performance,

separate all turns by at least 4 ft. of

straight duct, including distance

between last turn and exhaust hood.

Exhaust vent hood

The exhaust duct must end with an

approved exhaust vent hood with

swing out damper(s). DO NOT

use an

exhaust vent hood with magnetic

latches.
To avoid exhaust restriction, the outlet

must be a minimum of 12 inches (30

cm) above ground level or any other

obstructing surface.

Required parts

The parts required for the exhaust air

system (elbows, lines, exhaust air

outlets) are not included in standard

delivery of the dryer.

Accessories

The parts required for the exhaust air

system can be obtained from customer

service or your local dealer. Please

follow the installation instructions

supplied by the appropriate

manufacturer!

Side exhaust kit

part no.

WZ20365

Note:

The maximum permitted number of 90°

elbows (including this side exhaust kit)

is four!

i

Special tool for cutting the hole in

prepared side panel is required.

Contact local dealer!

Bottom exhaust kit

part no.

WZ20370

Note:

The maximum permitted number of 90°

elbows (including this side exhaust kit)

is four!