Date:

December 20, 1999

No. 137 Rev. 2

Subject:

Gas Water Heater Conversion Policy

To:

All Accounts

* This supersede all previous letters and field bulletins concerning residential and commercial water heater conversion.

GAS WATER HEATER CONVERSION POLICY

All A.O. Smith Water Products Company’s residential and commercial gas water heaters are designed certified by CSA or UL,
under ANSI Standards for operation on one type of gas only, as indicated on the water heater’s model number and rating
plate.

A.O. Smith realizes that there may be certain situations where a field conversion may be necessary and in order to facilitate
such a conversion, A. O. Smith complies with CSA or UL regulations ensuring that a field conversion be appropriately and
safely completed.

An improper field conversion from one type of gas to another could cause potentially dangerous conditions that may cause an
explosion or fire resulting in property damage, bodily injury or both.

A.O. SMITH WILL ONLY ALLOW THE CONVERSION OF GAS WATER HEATERS FROM LP GAS (PROPANE) TO
NATURAL GAS. THE CONVERSION OF A GAS WATER HEATER FROM NATURAL GAS TO LP GAS (PROPANE) IS
NOT ALLOWED UNDER ANY CIRCUMSTANCES.

A.O. Smith will provide kits as demand warrants through our Parts Department, phone no.
1-800-433-2545. Prices, dimensions and specifications are subject to change without notice.

Each conversion kit is to be installed by an A.O. Smith service agent or a gas utility serviceman in accordance with
A.O. Smith’s written instructions and all codes and requirements of the authority having jurisdiction. Failure to follow
instructions could result in serious injury or property damage. The utility performing this work assumes responsibility for
this conversion.

Changing the Input on Gas Water Heaters

The only changes to the input of a gas water heater allowed are:

Adjustments to match that shown on the rating plate of the heater. The installation instructions supplied with the
heater indicate if adjustments to input are a required procedure.

Changes made as required to adjust the heater for proper operation at high altitude as determined by a qualified
service technician. Service manuals include the proper procedure for adjusting heaters at high altitudes.

Conversion of Gas Water Heaters

The conversion of LP gas (Propane) to Natural gas is ONLY allowed providing:

The conversion is done as part of a gas utility’s program where propane appliances were installed anticipating the
completion of natural gas service to the area. The conversion must be done under the direct supervision of the
utility and by their service representatives.

Claims of damage or injury arising from the unauthorized conversion of any A.O. Smith water heater not design certified for
conversion will be the complete and total responsibility of the person or entity making the conversion.

If you have any questions regarding the above policy, please contact the A.O. Smith Parts Department at 1-800-433-2545 or
our Technical Information Center at 1-800-527-1953.

W

W

W

W

WA

A

A

A

ATER HEA

TER HEA

TER HEA

TER HEA

TER HEATER

TER

TER

TER

TER

B

B

B

B

BULLETIN

ULLETIN

ULLETIN

ULLETIN

ULLETIN

Printed in the U.S.A. 2574 04/00

No. 137 Rev. 2

A.O. SMITH WATER PRODUCTS CO., INC.

5621 W. 115TH STREET • ALSIP, ILLINOIS 60803

PHONE: 1-800-433-2545

FAX: 1-800-433-2515 • www.hotwater.com

PSD - Alsip, Illinois