Aga Ranges Berrington User Manual
Page 6
![background image](/manuals/41451/6/background.png)
5
FLOOR PROTECTION
It is recommended that this appliance is installed on
a solid, level, non combustible hearth conforming to
current Building Regulations.
Fig.7
The appliance is suitable for continuous operation
on solid mineral fuel and intermittent operation on
wood logs. This appliance has been tested using
seasoned wood logs and manufactured briquetted
smokeless fuel (Ancit) for closed appliances, sized
between 20g and 140g. Other fuels are commer-
cially available. Wood logs up to 400 mm long are
suitable. All fuels should be stored under cover and
kept as dry as possible prior to use.
LOCATION
There are several conditions to be considered in
selecting a location for your Berrington Stove.
a.
Position in the area to be heated- central
locations are usually best.
b.
Allowances for proper clearances to
combustibles.
Note: Sufficient space should be given around
the back and sides of the stove to allow
access to the air control damper.
INSTALLATION CLEARANCES
Maintain at least the following clearances to all
combustible material:
From the front
900 mm
From the Sides
150 mm
From the rear
150 mm
From the flue pipe
600 mm