Inspect and clean pump inlet filters

Check oil for correct level and consistency

Check pump for oil and water leaks

Check fittings for proper tightness

Change Oil every 300 hours

Packing Change

Valve Change

GENERAL TROUBLESHOOTING

IF THIS

CHECK THIS

Pump or Vac Does Not Turn On

Check the circuit breakers in the wall. If both cords were on one
circuit the breaker may have tripped.
The switches should light up when turned ON. Check the switch
to make sure it is working.

Pump Pressure is Low

Check the spray tip(s) for proper size or excessive wear.
The pressure relief valve may be stuck open, or the seat may be
worn.
Check the inlet filters for dirt or debris.
The pump inlet or outlet valves may be dirty or damaged.

Vacuum Suction is Low

Make sure the tank lid is closed tightly, the drain hose is closed
tightly, and the recovery hose is tight at the vac inlet hose barb
and at the tool.
Check the hose for cracks.

Water Leaking from Pump

Worn packing in pump.

Oil Leaking from Pump

Worn piston seals.
Misaligned oil seal O-Ring.
Bad bearing.
Damaged crankcase.

TORRENT PUMP MAINTENANCE SCHEDULE

It is critical that you maintain your pump properly in order to get the performance and longevity that it
can provide.
Change the oil in your pump after the first 50 hours of operation, then follow this maintenance schedule.

NOTE: if the oil shows signs of contamination (milky or discolored) change it immediately, and
replace the packings.
Keep a record of each task performed and the date completed.

DAILY

TASK

WEEKLY

AS

NEEDED

after the first one

at 50 hours

X

X

X

X

X

X

X