Anton/Bauer INTERACTIVE 2000 2400 User Manual
Page 10

8
Priority Battery Function
A unique operating feature of all PowerChargers allows the operator to select any 
battery on any charge position as a PRIORITY BATTERY. While connecting a battery 
to any charge position, hold the DISPLAY button until an audible indication sounds and 
the LCD indicates: 
The PowerCharger will interrupt the charging of any other battery and address the 
Priority Battery immediately (assuming it is within a safe charging parameters). When 
priority charging is complete, the charger will return to addressing the other batteries on 
the charger. 
NOTE: This function is unavailable if the AUTOCAL mode has been requested
by the charger.
DDM (DIAGNOSTIC/DISCHARGE MODULE)
(standard on Model QUAD 2702)
The DDM is a modular addition which will upgrade any InterActive 2000 
PowerCharger to a complete battery management system. A standard feature with the 
QUAD 2702, the DDM can be easily added to any model PowerCharger, at any time. 
With this module installed, the PowerCharger becomes a complete battery 
management system, capable of testing battery capacity and identifying battery 
anomalies before they appear in the field. 
The DDM will perform a standard or a 24 hour test. The standard test is a full 
charge-discharge-full charge routine, which will identify the capacity of the battery 
and indicate any performance issues, such as low battery voltage indicating a shorted 
cell. The 24 hour test is a full charge-wait 24 hours-discharge-full charge routine 
which will identify any excessive self-discharge or serious cell imbalance condition. 
Test time will vary with battery condition and watt hour rating. The standard test will 
require a minimum of 6 hours to a maximum of about 12 hours. The 24 hour test will 
require an additional 24 hours as the battery undergoes a 24 hour rest time to identify 
self-discharge anomalies. It is recommended that the 24 hour test be performed only on 
weekends or when the battery is not scheduled to be used for 2-3 days. 
PRIORITY BATTERY