NOTE: Clearances from noncombustible construction are the same as combustible clearances.
This appliance is suitable for installation only on noncombustible floors.
3. Place cook surface on top of unit. Be careful! This special cast iron top is more 1” thick and
is extremely heavy. Use a fork lift truck and three men to lift the top into position. Make sure
“ribs” on the bottom of the cook top do not sit on the support pipes.
4. Level the unit using the “bullets” at the end of each leg.
GAS INSTALLATION:
1. The installation must conform with the National Fuel Gas Code, ANSI Z223.1, Natural Gas
Installation Code, CAN/CGA-B149.1 or the Propane Installation Code, CAN/CGA-B149.2, as
applicable, including:
a. The appliance and its individual shutoff valve must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressures in excess of 1/2
psi (3.45 kPa).
b. The appliance must be isolated from the gas supply piping system by closing its individual
manual valve during any pressure testing of the gas supply piping system at test pressures
equal or less than 1/2 psig (3.45 kPa).
2. The installation must also conform with all local regulations governing gas appliance
installations.
3. If your unit is supplied with casters, the installation shall be made with a gas connector that
complies with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 or
Connectors for Moveable Gas Appliances, CAN/CGA-6.16, and a Quick Disconnect device
that complies with the Standard for Quick-Disconnect Devices for Use with Gas Fuel ANSI
Z21.41, or Quick Disconnect Devices for Use with Gas Fuel, CAN1-6.9, and adequate means
must be provided to limit the movement of the appliance without depending on connector and
the quick-disconnect device or its associated piping to limit the appliance movement.
4. If your unit is provided with casters on legs, the legs with locking casters must be installed opposite
the gas supply line. An approved restraining device must be secured to unit near gas supply.
3