Q c - 1 0 0, Roll, Unit must not be tipped on its side at any time – Alto-Shaam QC-100 User Manual
Page 2

20-1/4"
(641mm)
93-1/2" (2375mm)
58-1/2" (1486mm)*
27-3/4"
(705mm)*
DOOR NOT SHOWN
FOR CLARITY
8" (203mm)
ADJUST
ABLE
51" (1295mm)
35-1/2" (902mm)
41-1/8" (1045mm)
65-1/4" (1657mm) DOOR
30-1/2"
(775mm)
75" (1905mm)
ELECTRICAL
CONNECTION
65-1
1/16" (1668mm)
* Door opening
33-1/4"
(714mm)
Q C - 1 0 0
WITH
ROLL
-
IN CART
O P T I O N S & A C C E S S O R I E S
HACCP Network Software Options
■
■
HACCP Documentation
■
■
HACCP with Kitchen Management
REFER TO HACCP SPECIFICATION
#9015
FOR APPLICABLE PART NUMBERS
.
■
■
Prechill Sealing Strip
5008856
■
■
Roll-In Pan Cart (Trolley)
UN-27970
■
■
Wire Shelves, Stainless Steel
SH-22473
D I M E N S I O N S
(H x W x D)
EXTERIOR
:
95" x 51" x 41-1/8"
(2413mm x 1295mm x 1045mm)
INTERIOR
:
60" x 33-1/4" x 30-1/2"
(1524mm x 845mm x 775mm)
W E I G H T (
A P P R O X I M A T E
)
CABINET
ROLL
-
IN PAN CART
NET
1152 lb (523 kg)
120 lb (54 kg)
SHIPPING
1450 lb (658 kg)
161 lb (73 kg)
CRATED
55"
X
48"
X
98"
DIMENSIONS
:
(1397mm x 1219mm x 2489mm)
C L E A R A N C E R E Q U I R E M E N T S
BACK: 6" (152mm)
TOP: 6" (152mm)
SIDES: 4" (102mm) minimum at both sides.
18" (457mm)
MIN
.
FROM HEAT PRODUCING EQUIPMENT
.
P R O D U C T \ PA N C A PA C I T Y
MAXIMUM PRODUCT CAPACITY
—
Approximately 480 lb (218 kg), 300 quarts (380 liters)
MAXIMUM CHILLING CAPACITY
—
Approximately 240 lb (109kg), 150 quarts (190 liters)
FULL-SIZE PANS: 20" x 12" x 2-1/2" (GN1/1)
40
FULL-SIZE SHEET PANS: 18" x 26" x 1"
20*
*
ON WIRE SHELVES ONLY
.
EXTRA OPTIONAL WIRE SHELVES REQUIRED FOR
MAXIMUM CAPACITY SHOWN ABOVE
.
N
.
T
.
S
.
R E F R I G E R AT I O N
R404a Refrigerant
One (1) 3-1/2 hp Condensing Unit:
FREEZE MODE
: 20,940 BTU's per hour at -5°F (-21°C)
CHILL MODE
: 35,800 BTU's per hour at +20°F (-7°C)
E L E C T R I C A L
RECOMMENDED
VOLTAGE
PHASE
CYCLE
/
HZ
CIRCUIT AMPERAGE
208-240
1
50/60
60
RECOMMENDED WIRE SIZE
#6/2 w.g.
208-240
3
50/60
40
RECOMMENDED WIRE SIZE
#8/3 w.g.
380-415
3
50/60
30
RECOMMENDED WIRE SIZE
#10/2 w.g.
I N S TA L L AT I O N R E Q U I R E M E N T S
Unit must NOT be tipped on its side
at any time.
Tipping will cause damage to the unit
and void the warranty.
One (1) Floor Drain: 1/2" (12,7mm) diameter
Unit must be installed level. Unit must not be
installed in any area where it may be affected by
steam, grease, dripping water, high temperatures,
or any other severely adverse conditions.
#404
A
- 12/08
W164 N9221 Water Street • P.O. Box 450 • Menomonee Falls, Wisconsin 53052-0450 • U.S.A.
PHONE
: 262.251.3800 800.558.8744
U
.
S
.
A
./
CANADA
FAX
: 262.251.7067 800.329.8744
U
.
S
.
A
.
ONLY
www.alto-shaam.com
D U E TO O N G O I N G P R O D U C T I M P R O V E M E N T
,
S P E C I F I C AT I O N S A R E S U B J E C T TO C H A N G E W I T H O U T N O T I C E
.
P R I N T E D I N U
.
S
.
A
.