Options specifications, Applicable mil-std & ip, Knb-54n – Kenwood TK-5410D User Manual
Page 2: Knb-33l, Knb-43l, Knb-49pl, Kbp-6, Ksc-32, Kpg-93, Kra-32
ADS#40913 Printed in USA
Model
TK-5410D
GENERAL
Models
4-key w/LCD Model
TK-5410DK2
Full key w/LCD Model
TK-5410DK3
Frequency Range
Receive
763-776, 851-870 MHz
Transmit
763-776, 793-806, 806-825, 851-870 MHz
Number of Channels
1024
Zones
100
Max. Channels per Zone
512
Channel Spacing
Analog
12.5 / 25 KHz
Digital
12.5 kHz
PLL Channel Steps
12.5 kHz
Operating Voltage
7.5 VDC ± 20 %
Battery Life 5-5-90 (10-10-80) duty cycle
KNB-54N, 7.5 VDC, 2500 mAh
12 hours (8 hours)
KBP-6, AA Alkaline x6 Batteries (@ 1W)
8 hours (5 hours)
Operating Temperature Range
-22˚ F to +140˚ F (-30° C to +60° C)
Frequency Stability
± 1.5 ppm (-22° F to +140° F)
Antenna Impedance
50
Ω
Dimensions (W x H x D) (projections not included)
with KNB-54N
2.28 x 6.10 x 1.80 in. (58 x 155 x 45.7 mm.)
with KBP-6
2.36 x 6.10 x 1.84 in. (60 x 155 x 46.7 mm.)
Weight (Radio only)
4-key w/LCD Model
11.64 oz. (330 g)
Full key w/LCD Model
11.64 oz. (330 g)
Weight w/Antenna & Belt Clip (4-Key w/LCD Model)
with KNB-54N
23.28 oz. (660 g)
FCC ID
ALH468800
IC Certification
282D-468800
Model
TK-5410D
RECEIVER
Sensitivity
Digital (5 % BER)
0.25 µV
Digital (1 % BER)
0.40 µV
Analog 12 dB SINAD
0.25 µV
Selectivity
Digital
-60 dB
Analog @ 25 kHz
-75 dB
Analog @ 12.5 kHz
-64 dB
Intermodulation Distortion
-75 dB
Spurious & Image
-75 dB
Audio Distortion
Digital
Less than 1.0 %
Analog
Less than 2.0 %
Audio Output
500 mW / 8
Ω
TRANSMITTER
RF Power Output
3 W / 1 W
Spurious & Harmonics
70 dB
FM Hum & Noise
Analog @ 25 kHz
45 dB
Analog @ 12.5 kHz
40 dB
Audio Distortion
Less than 2 %
Modulation Limiting
Analog @ 25 KHz
± 5 kHz
Analog @ NPSPAC
± 4 kHz
Analog @ 12.5 KHz
± 2.5 kHz
Modulation
16K0F3E, 11K0F3E, 8K10F1E,
8K10F1D, 8K10F1W, 14K0F3E
■
KNB-54N
Ni-MH Rechargeable
Battery Pack (2500 mAh)
■
KNB-33L
Li-ion Rechargeable
Battery Pack (2000 mAh)
■
KNB-43L
Li-Polymer Rechargeable
Battery Pack (3300 mAh)
■
KNB-49PL
Primary Lithium Non-Rechargeable
Battery (4500 mAh)
■
KBP-6
Battery Case
■
KSC-32
Tri-chemistry
Rapid Charger
■
KPG-93
KVL Device Key
Loader Cable
■
KRA-32
700/800 MHz
Whip Antenna
■
KMC-42WD
MIL-STD & IP54/55/67
Speaker Microphone
(Future Availability)
■
KMC-52WD
MIL-STD & IP54/55/67
Digital Noise-canceling
Speaker Microphone
(Future Availability)
■
VGS-1
Voice Guide
& Storage Unit
■
KSC-326
Rapid Rate Six Unit Charger
for Ni-Cd/Ni-MH/Li-Ion
■
KVC-18/20L
D.C. Vehicular Charger
KVC-18 (for Ni-Cd/Ni-MH)
KVC-20L (for Li-ion/Li-Polymer)
■
KEP-1
Heavy Duty Earphone
■
KHS-11
2-Wire Palm Mic
with Earphone
All accessories and options may not be available in all markets.
Contact an authorized Kenwood dealer for details and complete list of all accessories and options.
Windows
®
is a registered trademark of Microsoft Corporation
in the United States and other countries.
AMBE+2™ is a trademark of Digital Voice Systems Inc.
The P25 Logo is used under license and is a registered
trademark of the Project 25 Technology Interest Group.
Specifications are subject to change without notice, due to advancements in technology.
Analog measurements made per TIA/EIA 603 and specifications shown are typical.
Digital measurements made per TIA/EIA 102CAAA and specifications shown are typical.
Options
Specifications
KNB-54N
*IP68: 3.3 feet (1m) depth @ 2 hours.
Applicable MIL-STD & IP
Standard
MIL 810C
MIL 810D
MIL 810E
MIL 810F
MIL 810G
Methods/Procedures
Methods/Procedures Methods/Procedures Methods/Procedures
Methods/Procedures
Low Pressure
500.1/Procedure I
500.2/Procedure I, II
500.3/Procedure I, II
500.4/Procedure I, II
500.5/Procedure I, II
High Temperature
501.1/Procedure I, II
501.2/Procedure I, II
501.3/Procedure I, II
501.4/Procedure I, II
501.5/Procedure I, II
Low Temperature
502.1/Procedure I, II
502.2/Procedure I, II
502.3/Procedure I, II
502.4/Procedure I, II
502.5/Procedure I, II
Temperature Shock
503.1/Procedure I
503.2/Procedure I
503.3/Procedure I
503.4/Procedure I, II
503.5/Procedure I
Solar Radiation
505.1/Procedure I
505.2/Procedure I
505.3/Procedure I
505.4/Procedure I
505.5/Procedure I
Rain
506.1/Procedure I, II
506.2/Procedure I, II
506.3/Procedure I, II
506.4/Procedure I, III
506.5/Procedure I, III
Humidity
507.1/Procedure I, II
507.2/Procedure II, III
507.3/Procedure II, III
507.4
507.5/Procedure II
Salt Fog
509.1/Procedure I
509.2/Procedure I
509.3/Procedure I
509.4
509.5
Dust
510.1/Procedure I
510.2/Procedure I
510.3/Procedure I
510.4/Procedure I, III
510.5/Procedure I
Vibration
514.2/Procedure VIII, X
514.3/Procedure I
514.4/Procedure I
514.5/Procedure I
514.6/Procedure I
Shock
516.2/Procedure I, II, V
516.3/Procedure I, IV
516.4/Procedure I, IV
516.5/Procedure I, IV
516.6/Procedure I, IV
Immersion
512.1/Procedure I
512.2/Procedure I
512.3/Procedure I
512.4/Procedure I
512.5/Procedure I
International Protection Standard
Dust & Water
IP54/55
Dust & Water Jet Intrusion IP66
Immersion
IP67/68*