beautypg.com

Attwood 1675 User Manual

Fuel surge protector 1675 (in-line)

background image

3

®

Attwood marine hardware, navigational lighting, bilge pumps, and other
marine accessories are specified more than any other brand by America’s
best-known boat manufacturers as original equipment. Look to Attwood
for quality replacement parts and marine accessories.

SAVE THESE INSTRUCTIONS

Form Number 69291 Rev. B

03-10

Fuel Surge Protector
1675 (In-Line)

© 2003 Attwood Corporation
1016 N. Monroe Street, Lowell, MI 49331-0260 www.attwoodmarine.com

Application
Designed to work on traditional tank vent systems with standard

⁵⁄₈

" (16mm) I.D. vent hose, the In-Line Fuel Surge Protector Installs:

• Directly into the vent hose above the top of the gas tank and

10" to 12" (254mm to 305mm) below the external vent.

• At a position within 45

°

of vertical so that the arrow with the

word VENT points upward toward the boat’s exterior vent.

CAUTION!
Surge Protector does not prevent water intake. Install Surge
Protector below an Attwood baffled P-Trap as a splash-resistant
vent outlet.

FEATURES
Even minor fuel spills can accumulate to be a serious environmen-
tal problem. The Vent Line Surge Protector helps you protect the
environment by reducing spills through the vent line on built-in fuel
tanks.

The Surge Protector easily attaches in-line to a standard

⁵⁄₈

"

(16mm) vent hose from the tank. The internal ball restricts flow out
the vent line when it senses a fuel surge from boat motion or
refilling. This prevents fuel from spilling through the vent.

INSTALLATION INSTRUCTIONS

1. If this is a new vent line installation, Attwood strongly

recommends installing a baffled vent trap that will restrict
entry of splashed water

into the vent line. The Attwood

P-Trap vents are good for this purpose.

If not installing a P-Trap, a hose loop

above the vent is

necessary to trap incoming water and return it through the
vent.

2. Select an installation location that meets these criteria:

• Vent hose is

⁵⁄₈

" (16mm) internal diameter, or is adapted to

that size

• Surge Protector is installed where it won’t be stepped on

or bumped

• Center of Surge Protector is 10" to 12" (254mm to 305mm)

below exterior vent

• Arrows and word “VENT” on the Surge Protector point up

• Surge Protector is installed vertically or at an angle no

greater than 45

°

3. Select a point in the vent hose 10" to 12" (254mm to 305mm)

below centerline of the vent. Remove a 2

¹⁄₂

" (64mm) section

of the hose.

4. Slide hose clamps over each end of the hose. For a problem-

free installation, use worm-drive 100% stainless steel clamps.

5. Hold the Surge Protector so arrows point up and the word

“VENT” points toward the boat’s exterior vent. Slide vent line
hoses fully onto the Surge Protector. Secure hoses with
clamps, but don’t overtighten.

6. Pressure test the fuel system to make certain there are no

leaks.

CARE AND MAINTENANCE
The Surge Protector is sealed to prevent contamination and can’t
be disassembled. No normal maintenance is required.

If the ball inside doesn’t rattle when shaken, or the Surge Protector
doesn’t work as intended, replace the Surge Protector.

ATTWOOD LIMITED WARRANTY
Attwood Corporation, 1016 North Monroe, Lowell, Michigan 49331 (“Attwood”)
warrants to the original consumer purchaser that Attwood brand products will be free
from defects in materials and workmanship under normal use and service for one year
from the date of original consumer purchases.

This limited warranty is not applicable if the product has been damaged by accident,
improper installation, unreasonable or improper use, lack of proper maintenance,
unauthorized repairs or modifications, normal wear and tear, or other causes not
arising out of defects in materials or workmanship.

Attwood products are warranted for use on pleasure boats. Any other use—including
but not limited to commercial, racing, or non-marine use—are not covered under this
warranty. Attwood’s obligation under this warranty is limited to repair of the product at
Attwood’s plant or replacement of the products at Attwood’s option without expense to
the original consumer purchaser. Any expenses involved in the removal, reinstallation
or transportation of the product are not covered by this warranty. The product must be
returned to Attwood’s plant at the address above, postage pre-paid, and insured with
proof of original purchase including date. If Attwood is unable to replace the product
and repair is not commercially practical or cannot be timely made, or if the original
consumer purchaser is willing to accept a refund in lieu of repair or replacement,
Attwood may refund the purchase price, less an amount for depreciation. The
acceptance by Attwood of any product returned or any refund provided by Attwood
shall not be deemed an admission that the product is defective or in violation of any
warranty. Products that are replaced or for which a refund is issued become the
property of Attwood.

This warranty is Attwood’s only expressed warranty of these products. No implied
warranty including, without limitation, the implied warranties of merchantability and
fitness for a particular purpose, shall be extended beyond the warranty period stated
above for each product. Attwood shall not be liable for any damages, for loss of use of
this product, nor for any other incidental or consequential damages, costs, or
expenses.

Some states do not allow limitations on how long an implied warranty lasts or the
exclusion or limitation of incidental or consequential damages, so the above limitations
and exclusions may not apply to you. This warranty gives you specific legal rights, and
you may have other rights which vary from state to state.

90

°

Vent Fitting

Single Clamps

8" Vent Hose

Fuel Vent

In-Line Fuel
Surge Protector

Tank

45

°

MAX.

10"-12"

Standards, Codes, Certifications:
Meets ABYC H-24.

Fuel tank installations must comply with ABYC, Federal or Local
requirements/laws for safety and to prevent spillage. All fuel
systems should be designed to prevent accidental spills and
damage to the environment. Check with NMMA or Attwood for
details.

The Federal Pollution Control Act prohibits the discharge of oil or
oily waste into or upon navigable waters of the United States or the
contiguous zone if such discharge causes a film or sheen upon or
discoloration of the surface of the water. Violators are subject to a
penalty of $5,000.